background image

11

Safety Notices

Safety Notices

1. 

Read, follow, and keep these instructions.

2. 

Heed all warnings.

3. 

Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in location that can be 

submerged by water. 

WARNING:

 Avoid using this product during an electrical storm. 

There may be a remote risk of electric shock from lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

General Warranty

UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and 

warrants that the Products furnished hereunder shall be free from defects 

in material and workmanship for a period of one (1) year from the date 

of shipment by UBIQUITI NETWORKS under normal use and operation. 

UBIQUITI NETWORKS sole and exclusive obligation under the foregoing 

warranty shall be to repair or replace, at its option, any defective Product 

that fails during the warranty period. The expense of removal and 

reinstallation of any item is not included in this warranty.
The foregoing warranty is exclusive and in lieu of all other warranties, 

express or implied, including the implied warranties of merchantability and 

fitness for a particular purpose and any warranties arising from a course 

of dealing, usage or trade practice with respect to the products. Repair or 

replacement in the manner provided herein shall be the sole and exclusive 

remedy of Buyer for breach of warranty and shall constitute fulfillment 

of all liabilities of UBIQUITI NETWORKS with respect to the quality and 

performance of the Products. UBIQUITI NETWORKS reserves the right 

to inspect all defective Products (which must be returned by Buyer to 

UBIQUITI NETWORKS factory freight prepaid).
No Products will be accepted for replacement or repair without obtaining 

a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS. 

Products returned without an RMA number will not be processed and will 

be returned to Buyer freight collect. UBIQUITI NETWORKS shall have no 

obligation to make repairs or replacement necessitated by catastrophe, 

fault, negligence, misuse, abuse, or accident by Buyer, Buyer’s customers or 

any other parties. The warranty period of any repaired or replaced Product 

shall not extend beyond its original term.

Summary of Contents for airMAX AM-3G18-120

Page 1: ...3 GHz 2x2 MIMO BaseStation Sector Antenna Model AM 3G18 120...

Page 2: ......

Page 3: ...tallation of the antenna Package Contents Carrier Class 3 GHz 2x2 MIMO BaseStation Sector Antenna Model AM 3G18 120 Antenna Protective Shroud Quick Start Guide U Brackets Qty 2 Pole Brackets Qty 2 Pol...

Page 4: ...AC ground of the PoE We recommend that you protect your networks from the most brutal environments and devastating ESD attacks with industrial grade shielded Ethernet cable from Ubiquiti Networks For...

Page 5: ...ables to the connectors labeled Chain 0 and Chain 1 on the RocketM 2 Attach the RocketM to the Rocket Mount Bracket a Align the mounting tabs on the back of the RocketM with the four mounting slots on...

Page 6: ...r ends of the RF Cables to the RF Connectors on the antenna 4 Slide the Protective Shroud down over the RocketM until it locks onto the Rocket Mount Bracket Note If you have trouble locking the shroud...

Page 7: ...h the Slotted U Bracket to the upper Mounting Lugs of the antenna and secure it with two M8 Serrated Flange Nuts 6 Attach the other U Bracket to the lower Mounting Lugs of the antenna and secure it wi...

Page 8: ...6 airMAX AM 3G18 120 Quick Start Guide 7 Insert two M8x135 Carriage Bolts into each Pole Bracket 8 Attach each Pole Bracket to each U Bracket using two M8x20 Serrated Flange Bolts Hand tighten only...

Page 9: ...unting assembly can accommodate a 1 5 3 0 pole a Slide the Pole Clamp over the two M8x135 Carriage Bolts of the lower Pole Bracket Secure it with two M8 Serrated Flange Nuts Lower Bracket Connection O...

Page 10: ...o M8x135 Carriage Bolts of the upper Pole Bracket Secure it with two M8 Serrated Flange Nuts Upper Bracket Connection Overview M8x135 Carriage Bolts Pole Clamp Pole Bracket M8x20 Serrated Flange Bolt...

Page 11: ...en the two M8x20 Serrated Flange Bolts on the Slotted U Bracket Slide the antenna to the desired tilt The upper bracket may slide along the pole depending on the angle of the elevation tilt Tighten al...

Page 12: ...3 3 8 GHz Gain 17 3 18 2 dBi HPOL Beamwidth 118 6 dB VPOL Beamwidth 121 6 dB Elevation Beamwidth 6 Electrical Downtilt 3 Max VSWR 1 5 1 Polarization Dual Linear Cross Pol Isolation 28 dB Min ETSI Spe...

Page 13: ...lace at its option any defective Product that fails during the warranty period The expense of removal and reinstallation of any item is not included in this warranty The foregoing warranty is exclusiv...

Page 14: ...ITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance including coverage buyer s selection of products for buyer s application and or failure of...

Page 15: ...ktronische Ger te ber die daf r zust ndigen und von der Regierung oder rtlichen Beh rden dazu bestimmten Sammelstellen zu entsorgen Ordnungsgem es Entsorgen und Recyceln tr gt dazu bei potentielle neg...

Page 16: ...les pouvoirs publics locaux le service de traitement des d chets ou l endroit o vous avez achet le produit Italiano La direttiva europea 2002 96 EC richiede che le apparecchiature contrassegnate con...

Page 17: ...tatud direktiivist tulenevatele teistele asjakohastele s tetele Suomi Finnish UBIQUITI NETWORKS vakuuttaa t ten ett UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatim...

Page 18: ...avky a v etky pr slu n ustanovenia Smernice 1999 5 ES Svenska Swedish H rmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device st r I verensst mmelse med de v sentliga egenskapskrav och vri...

Page 19: ......

Page 20: ...Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks...

Reviews: