STEP 4   Vertical Pull Test 
 

Lift up vertically on the UbiCell to 
confirm that the hooks are fully 
engaged. 

 
 
STEP 5   Dimming Test 

 

When correctly installed, the UbiCell 
should follow the following flash 
patterns based on expected 
functionality: 
 

If the luminaire supports dimming 
functionality

, there will be 3 flashes 

(on/off) for one second each. 

If 

dimming is not available

, there will 

be no flashes. 
 
If the expected results are not 
achieved, check the line power. If 
power is confirmed, perform a second 
vertical pull test to validate that the 
pins were properly rotated into the 
sockets in Step 3. If proper 
installation is confirmed, then mark 
the UbiCell for return and install a 
new UbiCell. 

 

STEP 6    Glove Test 

 

Cover the UbiCell or ALS entirely 
with a glove or other blacked-out 
material to trigger photocell and turn 
on the lamp.  
 
If the glove test fails, check the line 
power. If power is confirmed, 
perform a second vertical pull test to 
validate that the pins were properly 
rotated into the sockets in Step 3. If 
proper installation is confirmed, then 
mark the failed UbiCell for return and 
install a new UbiCell. 

 

 

 

Summary of Contents for UbiCell UG CAT-M

Page 1: ...herein is CONFIDENTIAL PROPRIETARY INFORMATION OF UBICQUIA INC and may not be copied or reproduced in whole or part nor disseminated to others without the express written approval of Ubicquia Inc 2060...

Page 2: ...CONFIDENTIAL PROPRIETARY INFORMATION OF UBICQUIA INC and may not be copied or reproduced in whole or part nor disseminated to others without the express written approval of Ubicquia Inc 2060 rev2 Clie...

Page 3: ...ure It should never be installed inside a fixed closure or cabinet The external NEMA UbiCell should not be installed in non ventilated areas The UbiCell is subject to atmospheric environmental conditi...

Page 4: ...lution occurs except that occasionally a temporary conductivity caused by condensation is to be expected Pollution Degree 3 Conductive pollution occurs or dry non conductive pollution occurs which bec...

Page 5: ...cle does not rotate If the receptacle rotates ensure it is locked in place before installing NOTE If the receptacle cannot be locked in place then it must be held in place during UbiCell installation...

Page 6: ...l be 3 flashes on off for one second each If dimming is not available there will be no flashes If the expected results are not achieved check the line power If power is confirmed perform a second vert...

Page 7: ...elect with option for DALI External Sensors UbiSmart AQM use DALI or PWM Auto select with option for Analog Input 0 10V NOTE Pins 6 7 of the NEMA ANSI C136 41 twist lock photocell connector must never...

Reviews: