Technical Specifications & Dimensions 

UbiCell Dimensions 
 

        

 

 
UbiCell Technical Specifications 
 

RECEPTACLE: 

NEMA 7-PIN 

PURPOSE OF CONTROL: 

OPERATING CONTROL 

CONSTRUCTION OF CONTROL: 

PLUG-IN - LOCKING TYPE 

OPERATING VOLTAGE: 

UP TO 506V 

IMPULSE VOLTAGE: 

4000V 

ACTION TYPE: 

TYPE 1 

POLLUTION DEGREE*: 

STANDARD WARRANTY: 

5 YEARS 

RATING: 

OUTDOOR/IP66 Enclosure 

CERTIFICATIONS

UL

 60730 

FCC ID

: XMR202008EG91NAXD (QUECTEL 

Model: EG91) 

FCC ID

XMR2020BG95M2

 (QUECTEL Model: 

BG95) 

*

Pollution Degrees Explained: 

Pollution Degree 1 

No pollution or only dry, non-conductive pollution occurs. The pollution has no influence.  

 

Pollution Degree 2 

Only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be 
expected.  

 

Pollution Degree 3 

Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to 
be expected.  

 

Pollution Degree 4 

Continuous conductivity occurs due to conductive dust, rain or wet conditions.

 

Note

: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his own expense.

  

Changes or modifications not expressly approved by Ubicquia could void the user's authority to operate the equipment. 

 

 

Summary of Contents for UbiCell UG CAT-M

Page 1: ...herein is CONFIDENTIAL PROPRIETARY INFORMATION OF UBICQUIA INC and may not be copied or reproduced in whole or part nor disseminated to others without the express written approval of Ubicquia Inc 2060...

Page 2: ...CONFIDENTIAL PROPRIETARY INFORMATION OF UBICQUIA INC and may not be copied or reproduced in whole or part nor disseminated to others without the express written approval of Ubicquia Inc 2060 rev2 Clie...

Page 3: ...ure It should never be installed inside a fixed closure or cabinet The external NEMA UbiCell should not be installed in non ventilated areas The UbiCell is subject to atmospheric environmental conditi...

Page 4: ...lution occurs except that occasionally a temporary conductivity caused by condensation is to be expected Pollution Degree 3 Conductive pollution occurs or dry non conductive pollution occurs which bec...

Page 5: ...cle does not rotate If the receptacle rotates ensure it is locked in place before installing NOTE If the receptacle cannot be locked in place then it must be held in place during UbiCell installation...

Page 6: ...l be 3 flashes on off for one second each If dimming is not available there will be no flashes If the expected results are not achieved check the line power If power is confirmed perform a second vert...

Page 7: ...elect with option for DALI External Sensors UbiSmart AQM use DALI or PWM Auto select with option for Analog Input 0 10V NOTE Pins 6 7 of the NEMA ANSI C136 41 twist lock photocell connector must never...

Reviews: