background image

Installation and putting into operation 

11 

printed: 07/2023  Subject to change! 

 

 RoFryUserManual.docx 

4.4  Tap 

 

Note!

  In  general  all  Installation  and  Service  work  has  to  be  done  by  an  authorized 

service  technician!  The  following  regulations  have  to  be  observed:  DIN  EN  1717  (alt 
DIN 1988, Part4, technical regulations for drinking water installation/TRW. 

 

 

 

 

  RoFry

®

 requires a cold water connection; we recommend using a water-softening unit in case of 

hard water above 6° dH (

=

 Level 1). 

 

Use flexible pressure hose ½“ with ¾“ screw joint. A faucet as well as a flow-back-prevention has 
to be provided on site. 

  Water pressure should be between min. 100 kPa and max. 400 kPa. Use a pressure reducer in 

case of water supply pressures above 400 kPa. 

 

4.5  Sewage 

Note!

 In general all Installation and Service work has to be done by an authorized ser-

vice technician! The following regulations have to be observed: DIN EN 1717 (alt DIN 
1988, Part4, technical regulations for drinking water installation/TRW. 

 

 

 

 

  The appliance needs an open sewage-connection, preferably ending in a funnel. UBERT recom-

mends  a  common flexible  sewage-hose  with  ¾ 

“diameter to be fixed to the sewage connection 

coming with the machine. 

4.6  Cleaner & Rinsing Agent 

Connect the cleaner and the rinsing agent canister with the RoFry using the tubes supplied with the 
machine. Make sure that these tubes are routed away from any hot parts and that they do not kink! 

4.7  Exhaust 

For an average capacity utilization of 60 %  (equals a continual preparation  of 1000g frozen goods 
of -18°C) there is an amount of exhaust of app. 130 m³/h that contains 6 kg water as hot steam. The 
steam has to be disposed by an extraction system. The best solution for this is an adequate hood-
system. If this is not possible because of the rooming situation other solutions can be found. In this 
case please contact our service members they will be glad to assist you. 

4.8  Preparation of Using / Starting up 

Before  you  can  use the  RoFry

®

  you  have  to  clean  all  removable  parts  carefully  with  a  grease  sol-

vent. 

Note!

  Do  not  use  flammable  cleaners.  Do  not  use  high-pressure-,  water  pressure-  or 

steam jet- cleaning devices. You will have further information about this in the  section 
‘cleaning and up keeping’ 

 

After cleaning the RoFry

®

 properly the smell will be minimal when using it the first time. 

Summary of Contents for RoFry RF-300-CC

Page 1: ...User Manual RoFry RF 300 330 360 CC...

Page 2: ......

Page 3: ...n 10 4 1 Unwrapping 10 4 2 Installation 10 4 3 Electrical connection 10 4 4 Tap 11 4 5 Sewage 11 4 6 Cleaner Rinsing Agent 11 4 7 Exhaust 11 4 8 Preparation of Using Starting up 11 5 Operation 12 5 1...

Page 4: ...it who Are familiar with the fundamental regulations of work safety and accident avoiding and who have been instructed how to operate the unit Read and understood the chapter about safety and warning...

Page 5: ...no working condition Disobeying of the references in the operating manual concerning transportation storage installa tion start up operation maintenance and assembling of the unit Unauthorized mechani...

Page 6: ...may only work at the unit under supervision of an experienced person 2 5 4 Unit control Under no circumstances it is allowed to make changes to the source code of the soft ware Only instructed person...

Page 7: ...nintended pushing Check all screw connections for tight fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structural changes to the unit Do not perform any ch...

Page 8: ...s wrong handling and levels out different amounts and temperatures 3 2 Special features compact design computer controlled self diagnostic fault finding system easy to operate with two buttons no buyi...

Page 9: ...FryUserManual docx 3 3 3 Weight Type Net weight RF 300 330 360 CC 88 5 kg 3 3 4 Electrical details Type Version Load per Ph RF 300 330 360 CC Europe Version 400V 15 5kW 50 60Hz 3Ph with N 25 A 3 3 5 N...

Page 10: ...t with opened side panels take care that the unit is dis connected from the mains Even if the unit is switched off the cooling fan may start to run Not paying attention may result in injury Please lea...

Page 11: ...l UBERT recom mends a common flexible sewage hose with diameter to be fixed to the sewage connection coming with the machine 4 6 Cleaner Rinsing Agent Connect the cleaner and the rinsing agent caniste...

Page 12: ...are closed now The temperature drops Now the computer control adjusts RoFry automatically to the amount and temperature of the food product by shortening or lengthening the total cooking time to obta...

Page 13: ...ooking time period cooking tempera ture and cooking end time Main Switch to switch RoFry ON and OFF Basket Handle to open and close the basket for loading and unloading of food products Door Lock to o...

Page 14: ...rograms to cook a full batch of products at a time In the user parameter section you can adjust various personal preferences such as language accesss code factory default is 1965 date time select the...

Page 15: ...an choose between New to create a new cooking program Change to change an existing cooking program Copy to copy an existing cooking program Move to move an existing cooking program to a different loca...

Page 16: ...the basket clockwise or counterclockwise Set a cleaning prompt 0 24h afer which a cleaning must be started 0 no prompt Select which cleaning programs are available to the operator Set the frequency l...

Page 17: ...face clean watch out that there is always enough fresh air on the surface never contact the surface with rusty material Never use bleaching or chlorine cleaners 6 1 3 Detergents To make the cleaning f...

Page 18: ...back to home screen 6 3 Weekly Cleaning Beside the daily cleaning the following items need some special care on a weekly basis Leave current frying program by pressing the back key Enter cleaning mod...

Page 19: ...problem possible cause remedy food does not become crispy frying time too short temperature too low steam time too long extend processing time increase temperature shorten steam time food does not be...

Page 20: ...20 Maintenance printed 07 2023 Subject to change RoFryUserManual docx 6 5 Wiring Diagram 6 5 1 RF 300 330 360 CC 400V 50 60Hz 3Ph with N...

Page 21: ...move the basket and then open the door Switch off the RoFry at the main switch 2 Remove the old gasket by pulling it out and clean the notch of the seal remove grease and other residues 3 Assemble in...

Page 22: ...RoFryUserManual docx 5 Finally check proper placement of the seal in the notch 6 Insert lamella sheet and basketholder again Close the door Remove the old basket gasket by pulling it out 7 Clean the n...

Page 23: ...e RoFryUserManual docx 8 Put in the new seal Place the splice of the seal in the middle of the upper notch 9 Push the seal into the notch Make sure neither to stretch nor to forge the seal 10 Finally...

Page 24: ...0 Front cover RF 300 117396 2 Seitenblende RF 300 Side cover RF 300 117397 1 R ckwand RF 300 Rear cover RF 300 117403 1 Frontblende RF 330 RF 360 Front cover RF 330 RF360 117431 1 Bedienblende RF 330...

Page 25: ...2237 342245 342412 1 Sch tz 26A 220 240V 50 60Hz Contactor 26A 220 240V 50 60Hz 343180 1 RHK RoFry Ausf hrung 16 335 kw heating element RoFry 15 0 kw 230V 344115 1 R ndelmutter A2 DIN 467 M6 Knurled n...

Page 26: ...IN 7603 Seal copper 380607 1 Lager Flansch mit Einsatz Hochtempe ratur Bearing for use with motor basketdrive 380104 380615 1 Flansch f r L ftermotor ROFRY Flange for fan motor 380675 2 Gleitauflage K...

Page 27: ...Maintenance 27 printed 07 2023 Subject to change RoFryUserManual docx 6 8 Exploded views...

Page 28: ...28 Maintenance printed 07 2023 Subject to change RoFryUserManual docx...

Page 29: ...00 Side cover RF 300 419012 Bedienpaneel Scheibe RoFry Operator panel glass RoFry 419001 Scheibe Dekor RoFry Decor panel glass RoFry 117431 Bedienblende RF 330 Front cover RF 330 419012 Bedienpaneel S...

Page 30: ...Canister Refill basket Part No RF 5010 Scoop Part No RF 5011 French fries portioner Part No RF 5012 French fries bag rest Part No RF 5013 Store shelf Part No RF 5015 RoFry warming basin 230V 2 0kW 50...

Page 31: ...Maintenance 31 printed 07 2023 Subject to change RoFryUserManual docx 6 10 Declaration of Conformity...

Reviews: