background image

!

CAUTION

When the air filter is to be 
removed, do not touch the 
metal parts of the unit.

It may cause an injury.

Do not clean unit when 
power is on as it may cause 
fire and electric shock, it may
cause an injury.

Operation with windows 
opened may cause wetting
of indoor and soaking of 
household furniture.

When the unit is to be 
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close 
the window in storm or 
hurricane.

Use caution when unpacking and 
installing. Sharp edges could cause injury.

Do not clean the air 
conditioner with water.

Water may enter the unit and 
degrade the insulation. It may 
cause an electric shock.

This could injure the pet or
plant.

Do not put a pet or house 
plant where it will be
exposed to direct air flow.

Hold the plug by the head 
of the power plug when 
taking it out.

Ventilate the room well when
used together with a stove, 
etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

pets, plants, and art objects.

It may cause deterioration of 

quality, etc. 

It may cause failure of product 

or fire.

Do not use for special 
purposes.

Turn off the main power  
switch when not using the
unit for a long time.

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate 
supply by taking the power-plug out and contact a 
qualified service technician.

!

!

!

!

!

!

!

It may cause failure of 
appliance or accident.

Appearance may be 
deteriorated due to change
of product colour or 
scratching of its surface.

Do not place obstacles 
around air-inlets or inside 
of air-outlet.

Do not use strong deter-
gent such as wax or 
thinner but use a soft cloth.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or 
electric shock.

Ensure that the installation bracket of 
the outdoor appliance is not damaged 
due to prolonged exposure.

Do not place heavy objects on the 
power cord and ensure that the cord
is not compressed.

Operation without filters may

cause failure.

It contains contaminants and 

could make you sick.

Always insert the filters 
securely. Clean filter once 
every two weeks.

Do not drink water drained 
from air conditioner.

!

!

 3

Failure to do so may cause 
electric shock and damage.

Summary of Contents for MWK-15CRN1-BJ7

Page 1: ...87795011 MWK 15CRN1 BJ7 USER MANUAL 1 866 206 0888 3 years ans warranty garantie...

Page 2: ...for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replace...

Page 3: ...y cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric...

Page 4: ...deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit tu...

Page 5: ...air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is d...

Page 6: ...e The unit can be controlled by the unit control alone or with the remote Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CON...

Page 7: ...ction only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maxi...

Page 8: ...n the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see Operate on Fan Only section NOT...

Page 9: ...e will register in 5 seconds and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on When the unit is off there is no display...

Page 10: ...ress and hold the Up and Down Temp Timer buttons at the same time for 3 seconds Fresh Air Vent Control on some models Figure 1 VENT CLOSED Figure 2 VENT OPEN The Fresh Air Vent allows the air conditio...

Page 11: ...es not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by removing storm window while room air conditioner is being installed 4 Check for anything that could block...

Page 12: ...ips Screwdriver 7 16 Locking screw and Flat washer for window panels 3 4 Long Hex head Screw Safety Lock 1 2 Long screw and Locknut 3 4 Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head...

Page 13: ...our unit may come with internal packaging This packaging must be removed prior to installing the air conditioner back into the cabinet see Fig 5 4 Pry away front from cabinet sides as shown in Fig 3 5...

Page 14: ...rk center of window stool 2 Place cabinet in window with bottom stool angle firmly seated over window stool as shown Bring window down temporarily behind top angle to hold cabinet in place Stool Stool...

Page 15: ...rely 1 2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lo...

Page 16: ...2 WIDTH X inside model width plus twice the thickness of framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Inside Frame Height 18 47 9cm or18 45 7cm...

Page 17: ...g 1 below Level 5 16 to 3 8 3 4 plus trim thickness See Para 5 Fig 1 4 Secure bottom rail to wood frame with two large wood screws 1 2 5cm long using the two holes in the bottom of the channel resting...

Page 18: ...rame of 2x4 as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry w...

Page 19: ...washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug th...

Page 20: ...rn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 17 C 62 F To defrost the coi...

Page 21: ...rmal during excessively humid days Remote sensor some models Remote control not located within range Place remote control within 20 feet and at a Remote control signal obstructed Remove obstruction Ro...

Page 22: ...FEATURES OF REMOTE CONTROL 16 ft 5m 16 ft 5m of your 21...

Page 23: ...22...

Page 24: ...23...

Page 25: ...24...

Page 26: ...25 change is...

Page 27: ...26 LED LED LED is displayed is displayed in in...

Page 28: ...27 LED LED LED LED LED LED LED LED LED LED...

Page 29: ...ted to the closest service centre The product is guaranteed for 36 months if used for normal trade purposes and is valid for the original buyer only Any warranty is deemed invalid if the product has b...

Reviews: