Uberhaus 02435002 User Manual Download Page 8

Never try to repair or dismantle the air conditioner unit yourself – this will void your 

warranty. Any repairs or servicing must be done by an authorized service centre to reduce 

the risk of electric shock and personal injury.

 

 

Problem

 

 

Cause

 

 

Solution

 

The air 

conditioner does 

not work.

 

No power supply.

 

Connect to a functioning outlet 

and switch on.

 

The alarm light is on.

 

Empty the internal water 

container.

Timer function is active.

 

Deactivate TIMER function.

 

The air 

conditioner does 

not seem to 

perform.

 

Placed under direct sunlight.

 

Close curtains.

 

Windows or doors open, 

many people or a heat source 

in the room.

Close doors and windows, place 

an extra air conditioner.

 

Dirty filter

 

Clean the filter(s).

 

Air inlet or air outlet blocked.

 

Remove the blockage.

 

Room temperature lower than 

the selected value.

 

Change temperature selection.

 

The unit is noisy.

 

Unit is not level.

 

Place on an even, solid surface 

 

(less vibrations.)

 

The compressor 

does not work.

 

The overheat protection is 

probably activated.

 

Wait 30 minutes until the 

temperature has decreased, then 

turn the unit on again.

The remote 

control does not 

work.

 

Distance too long.

 

Make sure the remote control is 

correctly aimed at the control 

panel.

 

Remote control signal not 

detected by the control panel.

 

The batteries are drained

 

Replace the batteries.

 

To correct problems not mentioned in the table and/or if the recommended solutions fail to 

solve the problem, please contact an authorized service centre.

TROUBLESHOOTING SPECIFICATIONS

 

 

MODEL

 

Power source 

Cooling capacity 

Heating capacity 

Refrigerant

 

Maximum operating pressure

 

Dimensions (W x H x D)

 

 

 
 

PC14-01PMA 

120V ~ 60Hz 

14,000 BTU/H 

12,600 BTU/H 

R410A 

5.5 MPa (55 Kgf/cm

2

19” x 33” x 14” 

(47.6 x 84 x 35.8 cm) 

 

 
 
 
 
 
 
 

(CE) N 842/2006:

 

 

R410A is a fluorinated greenhouse gas covered by 

the Kyoto Protocol.

 

Its total global warming potential (GWP) is 1975

 

 
 
 
 
 
 
 
 

Please discard or recycle your product and its packaging 

according to your municipal bylaws. 

 
 
 
 
 
 
 
 

 

 

13 

14 

Summary of Contents for 02435002

Page 1: ...e staff is available to help you For help with product assembly to report damaged or missing parts or for any other information about this product please call our toll free number SAVE THIS MANUAL Kee...

Page 2: ...fore using 10 When the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard 11 If the remote control won t be used f...

Page 3: ...ning or dehumidification setting Unique sleep control function 120 Volt 60 Hz operation 1 8 meter cord with plug UNPACKING INSTRUCTIONS 1 Place the unit in the correct upright position before unpackin...

Page 4: ...C 90 F 4 TEMP This button lowers the set temperature by 1 C each time it is pressed to a minimum of 17 C 65 F Please check with Troubleshooting guide on page 14 if any of the above error messages are...

Page 5: ...l be decreased by 1 C after 1 hour Subsequently the temperature will be decreased by 2 C after 2 hours It will maintain this setting without further changes 9 E7 ERROR DISPLAY When the unit warns of f...

Page 6: ...after 3 seconds Please make sure that the rubber cap is locked on the drain hole and note that the exhaust pipe and the drain hose must be extended through the closest window when the unit is running...

Page 7: ...t place the unit under direct sunlight the unit will begin to fade 11 HELPFUL HINTS The unit is fitted with a special thermal cut off device When selecting the cooling function the unit should operate...

Page 8: ...lace on an even solid surface less vibrations The compressor does not work The overheat protection is probably activated Wait 30 minutes until the temperature has decreased then turn the unit on again...

Page 9: ...ces 4 3 Description du panneau de contr le 5 8 4 T l commande 9 5 Notice et conseils d entretien 10 11 6 Alimentation lectrique 12 7 Installation d chappement 13 8 Utilisation du kit pour fen tre 13...

Page 10: ...t ouvert et que le tuyau d chappement et le tuyau d vacuation sont d tach s et allong s jusqu la fen tre la plus proche 10 Si le cordon d alimentation est endommag par pr caution le faire remplacer pa...

Page 11: ...Fonction nocturne unique Branchement au r seau 120 Volt 60 Hz Cordon de 1 8 m quip d une prise CONSIGNES A SUIVRE LORS DU D BALLAGE 1 Avant de la d baller placer l unit dans la position verticale qui...

Page 12: ...temp rature pr s lectionn e de 1 C pression jusqu un minimum de 17 C 65 F La temp rature d sir e est obtenue plus ou moins rapidement en fonction de l environnement et des conditions dans lesquelles...

Page 13: ...1 C toutes les heures 9 L AFFICHEUR MENTIONNE L ERREUR E7 Si l afficheur mentionne cuve pleine d brancher l obturateur d eau situ au dos de l appareil et faite basculer l unit vers arri re pour vacuer...

Page 14: ...pement En mode de chauffage lorsque l eau s accumule dans la cuve et que le niveau maximal est atteint l appareil commence pomper pendant 60 secondes Si apr s 60 secondes de pompage l eau est toujours...

Page 15: ...Assurez vous que la tension du r seau est compatible avec le climatiseur Ins rez fermement la fiche du cordon lectrique dans la prise D branchez imm diatement l appareil en cas de fuite d eau Ne tire...

Page 16: ...ou la sortie d air S lectionner une autre temp rature L appareil est bruyant Placer l unit sur une surface plane et solide pour r duire les vibrations Le compresseur ne fonctionne pas Attendre 30 minu...

Page 17: ...ice pour parler un technicien au 1 866 206 0888 du lundi au vendredi de 8h 18 h heure normale de l Est RONA se r serve le droit de r parer ou remplacer le produit d fectueux sa discr tion Ce produit e...

Reviews: