CONTROL PANEL & DESCRIPTION 
OF FUNCTIONS

 

 

   

The time required to reach the desired set temperature will depend on 

the environment and the area in which the unit is operating in. 

For example, if the ambient temperature is too hot or the room is too large, 

the cooling may be less effective and it will take more time to reach the set 

temperature. 

 

5. LED DISPLAY

 

 

Indicates the temperature or the time setting. After any time set the display will 

return to the preset set temperature. 

Error Display

 

 

E1:    Indicates open circuit or short circuit in room temperature  sensor.  
E2:   Indicates open  circuit or short circuit in pipe temperature sensor. 

E7:   Indicates the  water container is full. 

     

1. POWER KEY

 

 

Press to turn unit "ON" or "OFF". 

 

2. FUNCTION

 

 

Press this key to select COOLING, HEATING, DEHUMIDIFICATION or FAN. 

 

In dehumidifying mode, when “dh” is displayed, temperature cannot be set. 

 

In fan mode, when “FF” is displayed, temperature cannot be set. 

 

When in standby mode( off mode), press [mode] (function key) for 10 seconds 

 

to switch temperature from Celsius to Fahrenheit . (note: default setting is 

 

Celsius) 

 

3. TEMP+

 

 

This button raises the set temperature by 1°C each time it is pressed, to a maximum of 

30°C (90°F) . 

4. TEMP-

 

 

This button lowers the set temperature by 1°C each time it is pressed, to a 
minimum of 17°C (65°F) 
 

 
Please check with Troubleshooting guide on page 14 if any of the above error 
messages are shown. 

 
6. SPEED

 

 

Press to select either LOW, MEDIUM, HIGH or AUTO fan speed. 

 

If "AUTO" is selected, the unit will choose to operate at maximum, middle or minimum fan speed 
automatically, according to the difference between room temperature and setting temperature. 
 
If "HIGH" is selected, the unit operates at maximum cooling capacity no matter what the setting 
temperature is. The "MEDIUM" OR “LOW" comes to the same. Automatically setting 

 

Dehumidify function: fan speed at LOW. Heating function: fan speed at LOW, MEDIUM, HIGH. 

 

7. PROGRAMMABLE TIMER

 

 

Programmable timer ON/OFF key. 

TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over. 

(Timer-on key correspond to the functional indicator light)

 

 

1. Press "Timer"key at stand-by status(off mode) to set the time. After setting the time, then 

choose the function you need.(cooling, heating, dehumidifying, and fan mode(FF).) 

 

2. Once the set hour has come to an end, the unit will turn on automatically. 

 

3. Press the "POWER" key before time out, the set time will be cancelled and the unit will turn on. 

After time setting, displaying time will flash for seconds. Please choose the function after the 

flashing is stopped. 

5

6

Summary of Contents for 02435002

Page 1: ...e staff is available to help you For help with product assembly to report damaged or missing parts or for any other information about this product please call our toll free number SAVE THIS MANUAL Kee...

Page 2: ...fore using 10 When the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard 11 If the remote control won t be used f...

Page 3: ...ning or dehumidification setting Unique sleep control function 120 Volt 60 Hz operation 1 8 meter cord with plug UNPACKING INSTRUCTIONS 1 Place the unit in the correct upright position before unpackin...

Page 4: ...C 90 F 4 TEMP This button lowers the set temperature by 1 C each time it is pressed to a minimum of 17 C 65 F Please check with Troubleshooting guide on page 14 if any of the above error messages are...

Page 5: ...l be decreased by 1 C after 1 hour Subsequently the temperature will be decreased by 2 C after 2 hours It will maintain this setting without further changes 9 E7 ERROR DISPLAY When the unit warns of f...

Page 6: ...after 3 seconds Please make sure that the rubber cap is locked on the drain hole and note that the exhaust pipe and the drain hose must be extended through the closest window when the unit is running...

Page 7: ...t place the unit under direct sunlight the unit will begin to fade 11 HELPFUL HINTS The unit is fitted with a special thermal cut off device When selecting the cooling function the unit should operate...

Page 8: ...lace on an even solid surface less vibrations The compressor does not work The overheat protection is probably activated Wait 30 minutes until the temperature has decreased then turn the unit on again...

Page 9: ...ces 4 3 Description du panneau de contr le 5 8 4 T l commande 9 5 Notice et conseils d entretien 10 11 6 Alimentation lectrique 12 7 Installation d chappement 13 8 Utilisation du kit pour fen tre 13...

Page 10: ...t ouvert et que le tuyau d chappement et le tuyau d vacuation sont d tach s et allong s jusqu la fen tre la plus proche 10 Si le cordon d alimentation est endommag par pr caution le faire remplacer pa...

Page 11: ...Fonction nocturne unique Branchement au r seau 120 Volt 60 Hz Cordon de 1 8 m quip d une prise CONSIGNES A SUIVRE LORS DU D BALLAGE 1 Avant de la d baller placer l unit dans la position verticale qui...

Page 12: ...temp rature pr s lectionn e de 1 C pression jusqu un minimum de 17 C 65 F La temp rature d sir e est obtenue plus ou moins rapidement en fonction de l environnement et des conditions dans lesquelles...

Page 13: ...1 C toutes les heures 9 L AFFICHEUR MENTIONNE L ERREUR E7 Si l afficheur mentionne cuve pleine d brancher l obturateur d eau situ au dos de l appareil et faite basculer l unit vers arri re pour vacuer...

Page 14: ...pement En mode de chauffage lorsque l eau s accumule dans la cuve et que le niveau maximal est atteint l appareil commence pomper pendant 60 secondes Si apr s 60 secondes de pompage l eau est toujours...

Page 15: ...Assurez vous que la tension du r seau est compatible avec le climatiseur Ins rez fermement la fiche du cordon lectrique dans la prise D branchez imm diatement l appareil en cas de fuite d eau Ne tire...

Page 16: ...ou la sortie d air S lectionner une autre temp rature L appareil est bruyant Placer l unit sur une surface plane et solide pour r duire les vibrations Le compresseur ne fonctionne pas Attendre 30 minu...

Page 17: ...ice pour parler un technicien au 1 866 206 0888 du lundi au vendredi de 8h 18 h heure normale de l Est RONA se r serve le droit de r parer ou remplacer le produit d fectueux sa discr tion Ce produit e...

Reviews: