Ubiflux W300(+) / W400(+) / W450+
7
6
Ubiflux W300(+) / W400(+) / W450(+)
Chapter 3
Version
3.1 Technical information
Ubiflux W300
Supply voltage [V/Hz]
230/50
Protection degree
IP30
Dimensions (w x h x d) [mm]
675 x 765 x 564
Duct diameter [mm]
Ø160
External diameter condensate discharge [mm]
Ø32
Weight [kg]
38
Filter class
G3 (F7 optional for supply)
Fan setting (factory setting)
1
2
3
Ventilation capacity [m
3
/h]
50
100
150
225
Permissible resistance ducts system [Pa]
3 76
11 - 28
26 - 66
56 - 142
Rated power (excl. preheater)[W]
9.0 - 9.2
13.7 - 15.2
22.0 - 29.2
46.8 - 66.2
Rated current (excl. preheater)[AA]
0.104 - 0.107 0.150 - 0.161 0.214 - 0.274 0.403 - 0.578
Max. rated current (with preheater switched on) [A]
6
Cos φ
0,368 - 0.374
0.391 - 0.416 0.447 - 0.463
0.505
Sound power Ubiflux W300
Ventilation capacity [m
3
/h]
90
150
210
300
Sound power
level Lw (A)
Static pressure [Pa]
50
100
50
100
50
100
50
100
Housing emission [dB(A)
30
33
38
38
44
46
50
52
Duct “from dwelling” [dB(A)]
33
34
39
42
45
46
54
54
Duct “to dwelling” [dB(A)]
44
47
52
55
60
60
67
67
In practice, the value may deviate 1 dB(A) as a result of measuring tolerances