COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS

Method A. 12” (304.8 mm) Clearance to Combustible Wall Member: 

Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) 
minimum wall thickness clay liner, construct a wall pass-through.  The clay 
liner must conform to ASTM C315 (Standard Speci

fi

 cation for Clay Fire 

Linings) or its equivalent. Keep a minimum of 12” (304.8 mm) of brick 
masonry between the clay liner and wall combustibles.  The clay liner 
shall run from the brick masonry outer surface to the inner surface of the 
chimney 

fl

 ue liner but not past the inner surface.  Firmly grout or cement 

the clay liner in place to the chimney 

fl

 ue liner.  

Method B. 9” (228.6 mm) Clearance to Combustible Wall Member: Using 

a 6” (152.4 mm) inside diameter, listed, factory-built Solid-Pak chimney 
section with insulation of 1” (25.4 mm) or more, build a wall pass-through 
with a minimum 9” (228.6 mm) air space between the outer wall of the 
chimney length and wall combustibles.  Use sheet metal supports fastened 
securely to wall surfaces on all sides, to maintain the 9” (228.6 mm) air 
space.  When fastening supports to chimney length, do not penetrate the 
chimney liner (the inside wall of the Solid-Pak chimney).  The inner end of 
the Solid-Pak chimney section shall be 

fl

 ush with the inside of the masonry 

chimney 

fl

 ue, and sealed with a non-water soluble refractory cement.  Use 

this cement to also seal to the brick masonry penetration.

Method C. 6” (152.4 mm) Clearance to Combustible Wall Member: 

Starting with a minimum 24 gage (.024” [.61 mm]) 6” (152.4 mm) metal 
chimney connector, and a minimum 24 gage ventilated wall thimble which 
has two air channels of 1” (25.4 mm) each, construct a wall pass-through. 
There shall be a minimum 6” (152.4) mm separation area containing 

fi

 berglass insulation, from the outer surface of the wall thimble to wall 

combustibles.  Support the wall thimble, and cover its opening with a 24-
gage minimum sheet metal support. Maintain the 6” (152.4 mm) space.  
There should also be a support sized to 

fi

 t and hold the metal chimney 

connector. See that the supports are fastened securely to wall surfaces on 
all sides.  Make sure fasteners used to secure the metal chimney connector 
do not penetrate chimney 

fl

 ue liner.  

Method D.  2” (50.8 mm) Clearance to Combustible Wall Member: Start 

with a solid-pak listed factory built chimney section at least 12” (304 mm) 
long, with insulation of 1” (25.4 mm) or more, and an inside diameter of 8” 
(2 inches [51 mm] larger than the 6” [152.4 mm] chimney connector). Use 
this as a pass-through for a minimum 24-gauge single wall steel chimney 
connector. Keep solid-pak section concentric with and spaced 1” (25.4 
mm) off the chimney connector by way of sheet metal support plates at 
both ends of chimney section.  Cover opening with and support chimney 
section on both sides with 24 gage minimum sheet metal supports. See that 
the supports are fastened securely to wall surfaces on all sides. 

NOTES:

1.   Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through 

system and the chimney wall, to but not past the inner 

fl

 ue liner face.

2.   A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a 

fl

 oor, or ceiling.

Summary of Contents for 1100

Page 1: ... 800 750 2723 www usstove com SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE French version is available for download from the United States Stove Company website http www usstove com La version française est disponible pour téléchargement à partir du s...

Page 2: ...er Our advertised BTU s are based on the first hour of operation at high burn rate burning cordwood CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT...

Page 3: ... Make sure that the baffle board above the air tubes is in place and undamaged DO NOT REMOVE TOOLS AND MATERIALS NEEDED FOR INSTALLATION 1 A 5 16 socket Best if using a power drill and a socket bit 2 A pair of pliers or channel locks 3 A power drill with an 1 8 drill bit to install sheet metal screws into connector pipe 4 Sheet metal screws 5 A non combustible floor protector as specified in this ...

Page 4: ...cut the 4 tabs and remove panel on the back of the stove Note Discard the panel Step 2 Fix the assembly to the back of the stove with the four screws provided THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES ASSEMBLY 1 24 ...

Page 5: ...ient heat distribution possible throughout the house The stove must therefore be installed in the room where the most time is spent and in the most spacious room possible Recall that wood stoves produce radiating heat the heat we feel when we are close to a wood stove Awood stove also functions by convection that is through the displacement of hot air accelerated upwards and its replacement with c...

Page 6: ...connector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossing a combustible wall must have a minimum clearance of 18 457 2mm To reduce flue clearances from combustible materials...

Page 7: ...e outlet cover must be of a design that DOES NOT close by means of a flap or trap door You must purchase a style that allows a continuous in flow of air and that has a rodent screen This adapter can be purchased from your dealer DRYER VENTING KIT INSTALLATION Follow the manufacturer s installation instructions for attaching the dryer vent kit to the home Then attach it to the adapter on the combus...

Page 8: ...upling pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room There should never be more than two 90 degrees elbows in the smoke exhaust system Installation of a barometric draft stabilizer fireplace register on a smoke ex...

Page 9: ...is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE 2 It must rise above the roof at least 3 0 9m from the uppermost point of contact 3 The chimney mu...

Page 10: ...sociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed ...

Page 11: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation ...

Page 12: ...4 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal suppo...

Page 13: ...ur wood stove The wood should have dried for 9 to 15 months such that the humidity content in weight is reduced below 20 of the weight of the log It is very important to keep in mind that even if the wood has been cut for one two or even more years it is not necessarily dry if it has been stored in poor conditions Under extreme conditions it may rot instead of drying This point cannot be over stre...

Page 14: ...ey creating potential conditions for a chimney fire TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual THE FIRST FIRES The fresh paint on your stove needs to be cured to preserve its qual...

Page 15: ...ELOADING Once you have obtained a good bed of embers you should reload the unit In order to do so open the air controls to maximum a few seconds prior to opening the stove s door Then proceed by opening the door very slowly open it one or two inches for 5 to 10 seconds before opening it completely to increase the draft and thus eliminate the smoke which is stagnant in a state of slow combustion in...

Page 16: ...ant to perform a visual inspection of the stove every time it is emptied in order to insure that no parts have been damaged in which case repairs must be performed immediately Inspect and clean the chimney and connector pipe periodically for creosote buildup or obstructions GLASS Inspect and clean the glass regularly in order to detect any cracks If you spot one turn the stove off immediately Do n...

Page 17: ...T 3 18 83045 WASHER 5 16 ID X 3 4 OD X 1 16 THK 3 Key Description Part Qty 19 69761 WELDMENT DAMPER 1 20 891987 PLASTIC KNOB 1 21 86709 ROD DAMPER 1 22 40598 CAST DOOR 1 23 892293 DOOR GLASS 1 24 69914 REAR ACCESS 1 25 891135 HANDLE SPRING LG NICKEL 1 26 891087 HANDLE SPRING PIN 1 27 891085 HANDLE BEARING 1 28 891086 HANDLE CLEVIS PIN 1 29 892196 HANDLE ROD 1 30 892294 HINGE PIN 2 31 88082 3 4 ROU...

Page 18: ...rt No Description Qty 36 25089 BLOWER HOUSING BACK 1 37 25090 BLOWER HOUSING FRONT 1 38 80442 80 CFM BLOWER 1 39 80090 THERMOSTAT 1 40 80109 STRAIN RELIEF BUSHING 1 41 80232 POWER SUPPLY CORD 1 42 83172 10 x 1 2 SHEET METAL SCREW 8 ...

Page 19: ...EN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATIONAS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIPTION 3 THE MODEL NUMBER 4 THE SERIAL NUMBER HOW TO ORDER REPAIR PARTS U S Stove 227 Industrial Park Road South Pittsburg TN 37380 USA Phone 800 750 2723 www usstove com ...

Page 20: ...NOTES ...

Page 21: ...NOTES ...

Page 22: ...NOTES ...

Page 23: ..._______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the owner s manual that accompanies this unit and fully understand the Installation Operation and Maintenance of my new appliance Print Name Signature Date Please attach a copy of your purchase receipt Wa...

Page 24: ... CUT HERE CUT HERE Fold Here Fold Here U S Stove 227 Industrial Park Rd South Pittsburg TN 37380 USA Fold Here PLACE STAMP HERE ...

Reviews: