Part # 3052000 (09/16/09)
Page 31
REPLACEMENT OF PARTS Continued
Hi-Limit Control
1. Open the cabinet door.
2. Drain the oil from the frypot.
3. Disconnect the hi-limit wire from the terminals on the gas
valve.
4. Using a wrench, rotate the hi-limit body counter-
clockwise to remove.
5. Replace with new component and reassemble in the
reverse order.
Gas Control Valve
1. Open the cabinet door.
2. Disconnect the gas union at the inlet of the gas control.
3. Disconnect all wiring from the terminals on the gas
control valve.
4. Disconnect pilot tubing and thermocouple connections
at the gas control valve.
5. Swing pipe work forward so that the gas control valve is
clear to rotate. Disconnect from pipe work.
6. Replace with new component and reassemble in the
reverse order.
CAUTION: Ensure that the electrical supply to unit is
disconnected at the mains before attempting any service
on electric components.