7
YOU MUST TURN THE HEAT RECIRCULATION SWITCH OFF
BEFORE YOU CAN PRIME THE PUMP AND BEFORE YOU
BEGIN CLEANING, otherwise your pump pressure will be
very low.
BYPASS SWITCH:
The bypass switch (#6) completely bypasses the circuit locator system. Use this feature when you
cannot get the green Locator light (#5) to come on and you believe that the two cords are on separate
circuits.
CAUTION: If the bypass switch is on when the two cords are plugged into the same circuit,
the breaker may trip.
AUTO VACUUM SHUT-OFF:
When the recovery tank is full, the float system will shut off the vacuum motor to prevent the machine
from overflowing. The float may not work in foam. Always use a defoamer to prevent overflow. Once
the vacuum motor shuts off, the vac switch (#7) must be turned off, the recovery tank emptied, and then
the vacuum switch turned back on (up position) to get the vacuum motor started again.
CAUTION: Always make sure the float is clean and travels freely before turning on the
machine. A float that is stuck will cause the vacuum motor to suck in water, resulting in vac
motor damage.
PUMP PRESSURE:
Make sure the cleaning tool is spraying when adjusting the pressure, otherwise the pressure reading will
be inaccurate.
OPERATION CONTINUED