1
Make sure the recovery bucket is in place under the dome and in the correct position. The dome must be
fl
at or it won’t seal properly.
2
Fill the stainless steel holding tank with cleaning solution, to the desired level. Solution must be at least 3” above the
fi
lter in the bottom of
the tank.
NOTE
: Attach the exhaust hose when dry cleaning.
3
Position the cleaning tool over the holding tank, and depress the trigger. Turn the pump on (center switch). Allow the solution to spray for
several seconds, to
fi
ll the lines.
4
SOLVENT
HEATING:
turn on the Heater switch only. Make sure the Booster Heat switch is turned completely off. Wait two minutes for the
heater to reach operating temperature. Spray over the holding tank again, for about 15 seconds, to preheat the solution line and the tool.
NOTE
: the heat will shut off completely if the Booster Heat is turned on with solvent in the tank. Go to Step 5.
WATER
HEATING:
turn on the Heater switch, and position the Booster switch to the desired temperature. Wait 2 minutes for the heater to
reach operating temperature. Spray over the holding tank for 15 seconds to preheat the solution line and the tool. Wait 30 seconds, then
spray again for 15 seconds. Go to Step 5.
5
Turn on the Vacuum switch (
fi
rst switch). All rocker switches should be turned on now. You are now ready to begin cleaning.
6
When the recovery bucket is full, the vacuum will automatically shut off. Turn the vacuum switch off. Remove the dome and lift the bucket
out. Empty the bucket, and wipe off any spillage from the outside of the bucket. Reinstall the recovery bucket and the dome.
7
Make sure the
fl
oat in the bucket travels freely up and down the rod each time you empty the recovery bucket.
TO SWITCH CHEMICAL BASE
8
When switching from a solvent-based product to a water-based detergent, or vice versa, use the following procedure: turn off all the
switches, except the vacuum switch. Leave the vacuum hose in the dome, and disconnect the hoses from the tool. Place the open end of
the vacuum hose into the solution tank, and vacuum out any remaining solution. Place the hose over the
fi
lter in the tank for 10 seconds.
9
Connect the end of the solution line to the black suction plug. Take the vacuum hose out of the dome, and place the plug in its place. Let the
vacuum run for 20 - 30 seconds to pull all the solution out of the lines and the heater.
NOTE: DO NOT LET THE PUMP RUN DRY.
MAINTENANCE:
For optimum performance,
fl
ush the machine with clear water at the end of each working day. Once a month, minimum, run a
fl
ushing compound
through the machine to break up any mineral or chemical build-up that may have formed. Clean the
fl
oat rod each time the recovery bucket is
emptied. Inspect the
fi
lters regularly and clean as needed. The vacuum
fi
lter is located under the recovery bucket. The solution
fi
lter is located at
the bottom of the holding tank. The quick disconnects and castors can be lubricated with a penetrating spray lubricant. Fine steel wool will keep
the brass quick disconnects shinning. An auto interior spray cleaner/protectant will work well to keep the body clean and bright.