background image

SET-UP:

Make sure the recovery bucket is in place under the dome and in the correct position. The dome must be 

fl

 at or it won’t seal properly.

Fill the stainless steel holding tank with cleaning solution, to the desired level.  Solution must be at least 3” above the 

fi

 lter in the bottom of 

the tank.  

NOTE

:  Attach the exhaust hose when dry cleaning.

Position the cleaning tool over the holding tank, and depress the trigger. Turn the pump on (center switch). Allow the solution to spray for 
several seconds, to 

fi

 ll the lines.

4

 SOLVENT 

HEATING:

  turn on the Heater switch only.  Make sure the Booster Heat switch is turned completely off. Wait two minutes for the 

heater to reach operating temperature.  Spray over the holding tank again, for about 15 seconds, to preheat the solution line and the tool. 

NOTE

: the heat will shut off completely if the Booster Heat is turned on with solvent in the tank. Go to Step 5.

 WATER 

HEATING:

  turn on the Heater switch, and position the Booster switch to the desired temperature. Wait 2 minutes for the heater to 

reach operating temperature.  Spray over the holding tank for 15 seconds to preheat the solution line and the tool.  Wait 30 seconds, then 
spray again for 15 seconds.  Go to Step 5.

Turn on the Vacuum switch (

fi

 rst switch).  All rocker switches should be turned on now. You are now ready to begin cleaning.

When the recovery bucket is full, the vacuum will automatically shut off.  Turn the vacuum switch off.  Remove the dome and lift the bucket 
out.  Empty the bucket, and wipe off any spillage from the outside of the bucket.  Reinstall the recovery bucket and the dome.

Make sure the 

fl

 oat in the bucket travels freely up and down the rod each time you empty the recovery bucket.

 

TO SWITCH CHEMICAL BASE

When switching from a solvent-based product to a water-based detergent, or vice versa, use the following procedure:  turn off all the 
switches, except the vacuum switch.  Leave the vacuum hose in the dome, and disconnect the hoses from the tool.  Place the open end of 
the vacuum hose into the solution tank, and vacuum out any remaining solution.  Place the hose over the 

fi

 lter in the tank for 10 seconds. 

Connect the end of the solution line to the black suction plug.  Take the vacuum hose out of the dome, and place the plug in its place.  Let the 
vacuum run for 20 - 30 seconds to pull all the solution out of the lines and the heater.

  NOTE:  DO NOT LET THE PUMP RUN DRY.

MAINTENANCE:

For optimum performance, 

fl

 ush the machine with clear water at the end of each working day.  Once a month, minimum, run a 

fl

 ushing compound 

through the machine to break up any mineral or chemical build-up that may have formed.  Clean the 

fl

 oat rod each time the recovery bucket is 

emptied.  Inspect the 

fi

 lters regularly and clean as needed.  The vacuum 

fi

 lter is located under the recovery bucket.  The solution 

fi

 lter is located at 

the bottom of the holding tank. The quick disconnects and castors can be lubricated with a penetrating spray lubricant.  Fine steel wool will keep 
the brass quick disconnects shinning. An auto interior spray cleaner/protectant will work well to keep the body clean and bright.

revised 6/12

12/10

A - 5

 56041875 - PB111

ENGLISH - A 

INSTRUCTIONS FOR USE

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for PB111-120

Page 1: ...lution out of the solution tank and empty the recovery bucket after each job 9 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not us...

Page 2: ...n so that it can be inspected CLEANING SOLUTIONS The PB111 is capable of either wet or dry cleaning Only liquid cleaners are recommended no powders Solvents with a flash point of 140 F or higher are r...

Page 3: ...rom heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no longer than 50 feet Replace the cord or unpl...

Page 4: ...ect this plug to a 2 pole receptacle as shown in Figure 2 if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet Figure 1 can be inst...

Page 5: ...of the bucket Reinstall the recovery bucket and the dome 7 Make sure the float in the bucket travels freely up and down the rod each time you empty the recovery bucket TO SWITCH CHEMICAL BASE 8 When...

Page 6: ...CT BRASS FITTINGS AFTER USING THE BOOSTER HEAT THE FITTINGS CAN GET VERY HOT AND MAY CAUSE MINOR BURNS AUTO VAC SHUT OFF When the recovery bucket is full the vacuum motor will automatically shut off T...

Page 7: ...ther there is solvent or water base cleaning in holding tank Patented Unique fail safe system automatically prevents solvent from heating above 140 F regardless of heat setting Pump Centrifugal type 4...

Page 8: ...9 10 11 12 13 14 15 16 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 9 44 6 D 2 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d...

Page 9: ...1 240 FP654 1 Power Cord 300 240V model PB111 240 32 76A 1 Hose Clamp Ss 1 13 16 X 2 3 4 33 FP247 1 Repair Kit PB111 Heat System 34 SUB459 4 Louver 2 1 2 Grey Plastic W 35 FP440 1 Body Black Ultimate...

Page 10: ...6 Screw 1 4 20 X 1 2 Hwh Sl 5 4 Caster For Ultimate Chrome NOTE 1 6 1 Caster Plate Plastic Polypropi NOTE 1 7 SUB928 2 Louver 3 Grey Plastic Include NOTE 1 These items are not available for sale separ...

Page 11: ...Ms 7 429 1 Plate Heat Sink 8 447 1 Circuit Board 120 V Solvent all models except PB111 240 448 1 Circuit Board Solvent Sense model PB111 240 9 138A 1 Bolt Hex Ss 1 4 20x1 3 4 10 409A 1 Relay Solid St...

Page 12: ...models except PB111 240 includes 1 2 12 FP186 1 Pump Motor PB111 240V No Me model PB111 240 includes 1 2 12 12 435B 1 Pump Slide Bracket Male 13 SUB405 1 Pump Head Brass For Pb111 120 14 56478523 1 Ti...

Page 13: ...asher Flat Ss 10 6 33 1 Screw Bhs Brass 10 32x3 8 Ms 7 129 1 Bushing Zinc 4 40 X 1 2 8 131 2 Bushing Aluminum 10 32 X 1 9 145 1 Insert 531 X 1 4o D X 10 32 10 420 1 Handle Bucket Ss 3 16 11 421USP 1 R...

Page 14: ...3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 VACUUM CHAMBER ASSY revised 6 12 D 8 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0...

Page 15: ...Tape Cloth 2 X 60 Yds Bla 10 123USP 1 Reed Switch 5 16 24 X 1 1 11 156USP 2 Hose Clamp Size 28 1 9 16 2 1 2 12 19USP 3 Screw 4 40 X 3 4 Flathead 13 419USP 1 Gasket Ccns Psa 4 Idx1 2 Thick 14 FP163 1...

Page 16: ...OLUTION TANK ASSY revised 6 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D 10 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 17: ...Ss Zp 1 4 20 9 137 2 Washer Slitlock Ss Zp 1 4 10 425 11 5 Gasket 40 Shore Santoprene 11 425 21 Gasket 40 Shore Santoprene 12 426 1 Cover Pump 13 FP246 1 Solution Tank S S For PB111 Co 14 454 42 Pin...

Page 18: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 19: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 20: ...2 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8...

Reviews: