U.S. Products KING COBRA 1200 PRO Operating Instructions Manual Download Page 2

IMPORTANT SAFETY INSTRUCTIONS

This machine is only suitable for commercial use, for example in hotels, schools,
hospitals, factories, shops and offices other than normal residential housekeeping
purposes.

When using any electrical appliance, basic precautions should always be followed,
including the following:

NOTE: Read all instructions before using this machine.

WARNING!

To reduce the risk of fire, electric shock, or injury:

• Do not leave the machine unattended when it is plugged in.  Unplug the unit from the

outlet when not in use and before servicing.

• To avoid electric shock, do not expose to rain or snow.  Store, and use, indoors.
• Do not allow to be used as a toy.  Close attention is necessary when used near children.
• Use only as described in this manual.  Use only the manufacturer’s recommended attach-

ments.

• Never add water over 54 °C/130 °F to the solution tank.
• Do not use with damaged cord or plug.  If the machine is not working as it should, has

been dropped, damaged, left outdoors, or dropped into water return it to a service cen-

ter.

• Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the

cord around sharp edges or corners.  Do not run the machine over the cord.  Keep the

cord away from heated surfaces. To unplug, grasp the plug, not the cord.

• Do not handle the plug, the cord, or the machine with wet hands.
• Extension cords must be 12/3 and no longer than 50 feet.  Replace the cord or unplug

immediately if the ground prong becomes damaged.

• Do not put any object into openings.  Do not use with any opening blocked; keep free of

dust, lint, hair, and anything that may reduce air flow.

• Keep loose clothing, hair, fingers, and all parts of body away from openings and moving

parts.

• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot

ashes, or any health endangering dusts.  Do not use the machine to pick up flammable

or combustible liquids such as gasoline or use it in areas where they may be present.

• Turn off all controls before unplugging.
• Use extra care when cleaning on stairs.
• Connect to a properly grounded outlet only.

• Liquid ejected at the spray nozzle could be dangerous as a result of its

temperature, pressure, or chemical content.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for KING COBRA 1200 PRO

Page 1: ...spot 3 Before each use remove the spray tool from the hose and check to make sure the spray nozzle is securely tightened to the spray tool A loose nozzle could fly off during use 4 If a leak occurs a...

Page 2: ...by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug gras...

Page 3: ...nce a month minimum run a flushing compound through the machine to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motors and th...

Page 4: ...ection Auto fill Basket Wheel Recovery Dump Hose Castor Switches Auto Dump Pump Power Cord Recepticle Power Prime Pedal Base Compartment Vac Tank Latch Chemical Pick up hose Solution Tank 1200 PSI Qui...

Page 5: ...not connect both cords to the same outlet The green separate circuit locator light 1 on the switch plate should light up If the locator light does not come on check the circuit breaker box in the wal...

Page 6: ...and cleaning tools for cleanliness and completeness Make sure the recovery tank drain hose is closed and the lid is tight on the recovery tank Make sure the hoses are in good condition and the spray n...

Page 7: ...ure regulator cap lower front while you are spraying and watching the 500 psi pressure gauge NOTE the gauge will only read pressure while you are spraying 10 Spray for a few seconds to fill the lines...

Page 8: ...The autofill float will automatically shut off the flow of incoming water when the tank is nearly full and it will allow the valve to open again once the water level has dropped to a predetermined lev...

Page 9: ...hose into a drain Turn the dump pump switch ON switch is located on the switch panel on the top of the machine NOTE the dump pump will only run when the tank is full enough to activate the float swit...

Page 10: ...38 31 37 41 46 49 49 39 28 28 36 6 KC 1200 PRO 120V 11 2 2006 110 110A 82 72 83 79 69 68 74 75 104 101 102 83 105 106 107 108 111 78 79 121 122 123 128 127 124 138 139 140 142 143 66 112 80 99 to out...

Page 11: ...4 FP508 1200psipump motor complete 105 1062 Recepticle power cord 106 957 Pump auto dump 107 1324 HoseConnector dumppumpout 108 1325 Elbow auto dumpin 110 4405A Relay 20Amp 110A 2025 Heat sink plate 1...

Page 12: ...ent fully adjustable 0 500 psi Positive displacement 1200 psi 2 2 gpm 1500 Watts 16 gallon solution tank 14 gallon recovery tank two detachable 12 3 hospital grade plugs 39 H X 21 W X 36 L 5 5 gpm wit...