background image

Hoses

Vacuum 

Hose 

Connection

Wheel

Switches

Base      

Compartment

Latch

Solution 

Tank

1200 PSI

Quick

Disconnect

500 psi

Quick Disconnect

500 psi 

Gauge

500 psi 

Pressure

Adjust

Knob

KNOW YOUR MACHINE

1200 psi 

Gauge

Recovery Tank

Dump Hose

Castor

Auto-Dump 

Pump

   Power 

Cord 

Receptacle

Power Prime 

Pedal

Recovery 

Tank

Wand Holder

Wheel

Vacuum Hose

Connection

Recovery

Tank

Auto-fi ll 

Hose

Connector

Wand Holder

   Dump 

hose 

connection

3

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for KING COBRA 1200 PRO

Page 1: ...ring use 3 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not use outdoors 4 Never allow the spray to remain fixed in one spot 5 Use...

Page 2: ...e center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated su...

Page 3: ...ar of the pumps seals and other components Damage caused by the use of improper or strong chemicals is not covered by warranty Powdered chemicals are not recommended MAINTENANCE For optimum performanc...

Page 4: ...re Adjust Knob KNOW YOUR MACHINE 1200 psi Gauge Recovery Tank Dump Hose Castor Auto Dump Pump Power Cord Receptacle Power Prime Pedal Recovery Tank Wand Holder Wheel Vacuum Hose Connection Recovery Ta...

Page 5: ...1200 psi pump and the 500 psi pump at the same time 3 This light will turn on when the switch is set to the 1200 PSI pump 4 This switch turns on the vacuum 5 This switch turns on the 500 psi solution...

Page 6: ...n check the circuit breaker box in the wall and or try different outlets until it does turn on Although all systems in the machine may work correctly if you are not on two circuits a circuit breaker i...

Page 7: ...e the recovery tank drain hose is closed and the lid is tight on the recovery tank Make sure the hoses are in good condition and the spray nozzle s is tight 2 If you choose to use the auto dump featur...

Page 8: ...oat that hangs from the auto fill valve into the tank is free of obstruction and can move freely Turn on the water supply NOTE Do not turn the water pressure on high just turn the water on AUTO FILL A...

Page 9: ...h debris After each job run clear water though the dump pump to wash out any chemical residue Remove and clean the stainless steel filter in the bottom of the tank Reinstall the filter once it is clea...

Page 10: ...05 111 78 79 121 122 123 128 127 124 138 139 140 142 143 66 80 99 102 135A 75 111A 136 24 137 130 70 92 92 140 113 114 116 95 84 94 75 75 146 135 133 1 2 4 3 110B 110 110A 1 2 4 3 to item 20 30 29 28...

Page 11: ...1 Elbow 90 degree brass 1 4 mpt 21 1141 Washer S S 22 1146 Pipe S S 1 4 mpt both ends 23 1143 Spacer insulated 24 45 Quick Disconnect male 1 4 pt 25 1184 Hose connector inlet water supply line 26 1533...

Page 12: ...lift Ball Float Positive displacement fully adjustable 0 500 psi Positive displacement 1200 psi 2 2 gpm 2000 Watts adjustable up to 212 F 16 gallon solution tank 14 gallon recovery tank Two detachabl...

Reviews: