INSPECTION:

Carefully unpack and inspect your COBRA PLUS-150 for shipping damage.  Each machine is
tested and inspected before shipping.  Any shipping damage incurred is the responsibility of
the carrier.  You should notify the carrier immediately if you notice damage to the box or to
the machine or parts.

CLEANING SOLUTIONS:

We recommend liquid cleaning chemicals, such as our Magic Fabric Cleaner.  Powder chemicals
may be used, but unless mixed very thoroughly they could cause a build-up in the pump,
lines, heat exchanger and/or quick disconnects.  Any problem caused by a chemical build-up
is not covered by warranty.  Use a neutral cleaner with a pH between 6 and 9 to avoid
premature wear of the pump, seals, and/or other components.  Damage caused by the use of
strong chemicals is not covered by the warranty.

MAINTENANCE:

For optimum performance flush the machine with clear water at the end of each working day.
Once a month, minimum, run a flushing compound  through the machine to break up any
mineral or chemical build-up that may have formed.  U.S. Products “X-1500” is recommended.
Lubricate the wheels, castors, and quick disconnects with an all purpose silicone spray.  The
vacuum and the pump do not require any maintenance; however the vacuum motors may
require new brushes after 1000 - 1500 hours.  Clean the body with an all purpose detergent,
and protect it with an all purpose silicone spray like automobile interior polish.

RECORD AND KEEP THE FOLLOWING INFORMATION

And don’t forget to register your puchase to activate your warranty;

go on-line to www.usproducts.com or complete and return your warranty card

Serial Number: __________________
Model: CP-150_
Purchase Date:
_____________
Write the name and phone number of your distributor:

Summary of Contents for COBRA PLUS-150

Page 1: ...acuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors only 3 Do not let pump run dry 4 Use approved chemicals only NO SOL...

Page 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Page 3: ...emicals is not covered by the warranty MAINTENANCE For optimum performance flush the machine with clear water at the end of each working day Once a month minimum run a flushing compound through the ma...

Page 4: ...nfirms that the machine is on two separate circuits GREEN INDICATOR LIGHT 3 When this light is illuminated it confirms that the machine is on two separate circuits VACUUM 4 VACUUM 5 AND PUMP 6 SWITCHE...

Page 5: ...ank empty and clean the recovery tank 12 When finished with the job remove any unused solution from the solution tank and run a few gallons of clean water through the system Drain the recovery tank by...

Page 6: ...45 44 2 40 39 43 42 41 08 07 2007 CP 150 38 36 35 37 19 20 30 32 33 34 31 29 28 24 22 21 16 18 15 120V 23 23A 27 26 25 26A 14 49 48 47 1 17 40A 7 22 10 11 2 13 9 11 O I 212 F O I O I I O I I I 6 U S P...

Page 7: ...t includes probe thermistor control thermal cutout circuit board FP194A Heat repair kit includes probe thermistor control circuit board 923 PCB dual circuit sensor board Machines made before 7 22 05 F...

Page 8: ...tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum lid is not closed or gasket is damaged No power to motor Test the switch Test the vacuum motor Spraying too long Tr...

Reviews: