TROUBLE SHOOTING:

IF THIS OCCURS

CHECK THIS

NO SPRAY

Solution tank is empty, or 

fi

 lter is plugged up.

Clogged spray tip.
Pump not running.
Valve on wand not operating.
Solution hose not completely connected to hose or to machine.

PUMP DOES NOT RUN

This pump has a built-in pressure switch, so it only runs when you release the pressure by spraying.  
Make sure pressure has been released. Remove the hose from the outlet side of the pump and hold 
it over a bucket. Turn on the pump to see if water 

fl

 ows through the pump.  If so the problem is not in 

the pump.

LOW SUCTION

Debris is plugging cleaning tool or vacuum hose.  
Drain gate is not completely closed, or seals are damaged.
Vacuum dome is not seated or is damaged.

NO SUCTION

Ball in the 

fl

 oat is blocking air 

fl

 ow.  Turn off the vacuum so the ball will drop down.

No power to motor.  Does the switch light up?  If not, the switch may be bad or there may be no 
power getting to the switch. Check wiring connections.
Test the switch.    
Test the vacuum motor. 

LOW HEAT

Spraying too long.  Try spraying for 8 - 10 seconds, or about three strokes.  
Heat exchanger needs to be 

fl

 ushed.  

Wrong tool being used.  Too much water passing through. Longer hose or larger diameter hose, than 
standard.

NO HEAT

Heat is not turned on.  
No power in the wall outlet - check to see if the breaker has tripped.  
No power to the heat switch - check wiring for ‘opens.”  
No power out of heat switch. Replace switch. 

Summary of Contents for 56381300

Page 1: ...ent vacuum motor damage 2 Connect the machine to a properly grounded outlet only 3 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do no...

Page 2: ...aged Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow Keep loose clothing hair fingers and all parts of body aw...

Page 3: ...____________________________________________________________________ Be sure to register your purchase to activate your warranty 120VAC GROUNDING INSTRUCTIONS This appliance must be grounded If it sh...

Page 4: ...power cords on the same circuit and this can trip the circuit breaker in the wall GREEN TWO CIRCUIT INDICATOR 5 This light will automatically turn on when you have plugged the two power cords into se...

Page 5: ...e dilution instructions on the chemical label Use a chemical with a pH between 5 and 10 7 Turn on the vacuum 2 8 Begin cleaning 9 Use defoamer any time foaming occurs to prevent damage to the motor or...

Page 6: ...eaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged NO SUCTION Ball in the float is blocking air flow Turn off the vacuum so the...

Page 7: ...rranty Vacuum One 3 stage One 3 stage VAC Shutoff Ball Float Ball Float Pump 100 psi demand diaphragm pump 100 psi demand diaphragm pump Water Lift 137 137 Heat 180 F Maximum 180 F Maximum Heater 2000...

Page 8: ...e Ne mettre aucun objet dans les ouvertures Ne pas utiliser si une ouverture est bloqu e pr server de la poussi re des peluches des cheveux et de quoi que ce soit qui r duirait le d bit d air Tenir le...

Page 9: ..._____________________________ ____________________________________________________________________ Veiller enregistrer votre achat pour activer votre garantie INSTRUCTIONS VISANT LA MISE LA TERRE 120V...

Page 10: ...m me circuit et le disjoncteur mural pourrait se d clencher T MOIN LUMINEUX VERT DES DEUX CIRCUITS 5 Ce t moin lumineux s allumera automatiquement lorsque les deux cordons d alimentation sont branch...

Page 11: ...on et de dilution de l tiquette du produit Utiliser un produit chimique avec un pH entre 5 et 10 7 Mettre l aspiration en marche 2 8 Commencer nettoyer 9 Utiliser un agent antimousse chaque fois qu il...

Page 12: ...percule du drain n est pas compl tement ferm ou les joints d tanch it sont endommag s Le d me de l aspirateur n est pas bien fix ou endommag PAS DE SUCCION La balle du flotteur bloque le flux d air te...

Page 13: ...Flotteur Pompe 100 psi pompe membrane la demande 100 psi pompe membrane la demande Colonne d eau 137 po 347 cm 137 po 347 cm Chaleur 82 C 180 F maximum 82 C 180 F maximum l ment chauffant 2000 watts...

Page 14: ...ADVANTAGE 100H 1 2 3 4 7 8 14 15 16 17 18 19 20 20A 21 22 23 24 23A 23A 21 25 26 28 27 29 30 31 32 33 34 35 17 36 40 37 38 39 41 42 43 46 47 14A 29B 29A 29 29B 12 13 2 11 10B 10 10A 48 6 49 11 27 O O...

Page 15: ...X 48 23 53869A 1 Pump 100 psi 23A 108A 2 Hose barb 90 elbow 24 925 1 Hose 3 8 X 11 1 2 Item Ref No Qty Description 25 207A 1 Filter pump inlet 25A 92BUSP 1 Nipple PVC 26 2175 1 Lid solution tank 27 80...

Page 16: ...P GRN 14 AWG TO VAC BLK WHT BLK WHT BLK WHT BLK BLK WHT14 AWG 31 BLK 14 AWG 31 WHT 14 AWG 37 BLK 14 AWG 47 WHT12 AWG 27 BLK 12 AWG 27 BLK 14 AWG 4 BLK 14 AWG 5 WHT 14 AWG 5 WHT 14 AWG 5 6 5 BLU 14 AWG...

Page 17: ...ER BLK WHT BLK WHT BLK WHT BLK BLK WHT14 AWG 31 BLK 14 AWG 31 WHT 14 AWG 37 BLK 14 AWG 47 WHT12 AWG 27 BLK 12 AWG 27 BLK 14 AWG 4 BLK 14 AWG 5 WHT 14 AWG 5 WHT 14 AWG 5 6 5 BLU 14 AWG 44 WHT 14 AWG 44...

Page 18: ......

Page 19: ......

Page 20: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com...

Reviews: