background image

Page 6

SKU 92649

For technical questions, please call 1-800-444-3353

NOTE: In the above photo both Low Pressure Hose (19) and High Pressure Hose (17) 
are in the storage position and are attached to Solid Storage Connectors (6 & 7).

To Conduct a Performance A/C System Test:
1. 

A performance test indicates air conditioning system condition by measuring system 
pressures with the engine running.

2. 

Turn the Red Thumb Handle (11) and Blue Thumb Handle (11) clockwise to the CLOSED 
positions. See 

FIGURE 1, above.

WARNING:  DO NOT, AT ANY TIME, OPEN the Thumb Handles (11) or refrigerant will be 

leaked to the atmosphere and the A/C system may become contaminated.

3. 

Turn the Red Control Valve (22) and Blue Control (23) counterclockwise, to the CLOSED 
position.  See 

FIGURE 1 on page 6.

4. 

Connect the Red High Pressure Coupler (22) to the A/C system 

high

 side line.  Connect 

the Blue Low Pressure Coupler (23) to the A/C system on the

 low

 side line. 

 

See 

FIGURE 1, above.

Operation (continued)

Coupler (23) clockwise to open.

8. 

Note:  The pressure you see on both the high and low side gauges should be the same 
or very close.  Now, compare the reading taken to the reading as noted in the vehicle 
manufacturer’s service manual.

9. 

Turn the Control Valves of the Red High Pressure Coupler (22) and Blue Low Pressure 
Coupler  (23)  counterclockwise  to  close  and  remove  the  Couplers  from  the  A/C 
system.

10. 

Use care when disconnecting the Control Valves from the A/C system service fittings, 
the hoses may contain some residual refrigerant.

FIGURE 1

Blue Low Pressure Gauge (5)

Blue Thumb Handle (11)

Blue Low Pressure Coupler (23)

Control Valve

Blue Refrigeration 
Low Pressure 
Hose (19)

Red High Pressure Gauge (3)

Red Thumb Handle (11)

Red  High  Pressure  Coupler 
(22)

Control Valve

Red 

Refrigeration 

High Pressure 

Hose (17)

Yellow Refrigeration 

Charging Hose (18)

(connect to both branches 

of T-fitting (16))

Manifold Body (2)

REV 05f, 09i

Summary of Contents for 92649

Page 1: ...AZARD if done by an untrained or inexperienced technician REV 05f 09i Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in seriou...

Page 2: ...Always lock up this product and keep it out of reach of children 5 Use the right tool for the job There are certain applications for which this A C Manifold Gauge Set was designed It will do the job...

Page 3: ...influence of alcohol or drugs Read warning labels if taking prescription medicine to determine if your judgment or reflexes are impaired while taking drugs If there is any doubt do not operate the to...

Page 4: ...rostbite if it comes in contact with the skin Always follow the safety warnings and instructions provided by the manufacturer of R 134a refrigerant 5 Never disconnect any hose while the hose is under...

Page 5: ...General instructions for testing an A C system are outlined in this manual Specific procedures for each individual system type and model should be referenced in the vehicle manufacturer s specific A...

Page 6: ...Connect the Blue Low Pressure Coupler 23 to the A C system on the low side line See FIGURE 1 above Operation continued Coupler 23 clockwise to open 8 Note The pressure you see on both the high and low...

Page 7: ...onoxide emitted from a running engine is a colorless odorless gas that can cause injury and death if inhaled 7 Set the A C system for maximum cooling for about ten minutes to allow pressures to stabil...

Page 8: ...HOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS T...

Page 9: ...ntal or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of mercha...

Reviews: