U.S. Divers Impulse Service & Repair Manual Download Page 3

Service & Repair Manual - Impulse Second Stage

Doc. #1078-56

Introduction

This manual provides factory prescribed proce-

dures for the correct service and repair of the Im-
pulse second stage.  It is not intended to be used as
an instructional manual for untrained personnel.  The
procedures outlined within this manual are to be
performed only by personnel who have received
factory authorized training through a U.S. Divers

®

/

Aqua-Lung

®

 Service & Repair Seminar.

If you do not completely understand all of the

procedures outlined in this manual, contact U.S.
Divers Co., Inc. to speak directly with a Technical
Advisor before proceeding any further.

Warnings, Cautions, & Notes

Pay special attention to information provided in

warnings, cautions, and notes that are accompanied
by one of these symbols:

WARNING 

indicates a procedure or situation

that may result in serious injury or death if
instructions are not followed correctly.

CAUTION 

indicates any situation or tech-

nique that will result in potential damage to the
product, or render the product unsafe if in-
structions are not followed correctly.

NOTE 

is used to emphasize important

points, tips, and reminders.

Scheduled Service

Because the Impulse regulator, complete with a

first stage, is considered to be a life-supporting
product, it is extremely critical that it receives ser-
vice according to the procedures outlined in this
manual on a regularly scheduled basis; at least once
a year with normal or infrequent use.

NOTE

:  A unit that receives heavy or frequent

use, such as in rental, instruction, or commer-
cial applications, should be serviced at least
twice each year - or more often - depending on
the conditions of use and the manner in which
it is maintained.  (Refer to the care and mainte-
nance procedures outlined in the Impulse
Owner’s Manual.)

GENERAL GUIDELINES

1.

In order to correctly perform the procedures
outlined in this manual, it is important to follow
each step exactly in the order given.  Read over
the entire manual to become familiar with all
procedures before attempting to disassemble the
Impulse, and to learn which specialty tools and
replacement parts will be required.  Keep the
manual open beside you for reference while
performing each procedure.  Do not rely on
memory.

2.

All service and repair should be carried out in a
work area specifically set up and equipped for
the task.  Adequate lighting, cleanliness, and
easy access to all required tools are essential for
an efficient repair facility.

3.

Before beginning any disassembly, it is impor-
tant to first perform the Initial Inspection proce-
dure, and refer to Table 1 - Troubleshooting to
determine the possible cause of any symptoms
which may be present.

4.

As each regulator is disassembled, reusable
components should be segregated and not
allowed to intermix with non-reusable parts or
parts from other regulators.  Delicate parts,
including inlet fittings and crowns which contain
critical sealing surfaces, must be protected and
isolated from other parts to prevent damage
during the cleaning procedure.

5.

Use only genuine factory parts purchased di-
rectly from U.S. Divers (or an authorized dis-
tributor outside of the U.S.) when servicing any
U.S. Divers/ Aqua-Lung product.  Substitution
with another manufacturer’s parts constitutes an
after-market modification of the product, and
renders all warranties null and void.

6.

Do not attempt to reuse mandatory replacement
parts under any circumstances, regardless of the
amount of use the product has received since it
was manufactured or last serviced.

7.

Do not overtighten parts beyond their torque
specification when reassembling.  Most parts are
made of either marine brass or plastic, and can
be permanently damaged by undue stress.

Summary of Contents for Impulse

Page 1: ...Impulse SecondStageRegulator P O Box 25018 3323 W Warner Ave Santa Ana CA 92799 5018 Copyright 1997 U S Divers Co Inc Doc No 1078 56 Authorized Aqua Lung Dealer SERVICE REPAIR MANUAL...

Page 2: ...Testing Procedures 10 Second Stage Air Flow Test 12 Second Stage Opening Effort Test 12 Second Stage Purge Flow Test 12 External Leak Test 12 Subjective Breathing Test 13 Table 1 Troubleshooting Guide...

Page 3: ...es outlined in the Impulse Owner s Manual GENERAL GUIDELINES 1 In order to correctly perform the procedures outlined in this manual it is important to follow each step exactly in the order given Read...

Page 4: ...tage with a stable intermediate pressure of 140 psi 5 with no open ports or hoses 2 Connect the first stage to a cylinder that is filled with 3 000 psi and open the cylinder valve to pressurize the re...

Page 5: ...mouthpiece 15 from the box bottom Inspect the mouth piece to ensure it is free of any tears or cuts that may cause leakage of water into the second stage or other discomfort Discard or set the mouthp...

Page 6: ...the washer 29 for any signs of wear or damage and discard if found 14 Remove and discard both O rings 30 31 and set the adjust ment knob aside to be cleaned separately in a mild acid bath white vineg...

Page 7: ...the polished sealing surface If damage is found discard the crown and do not attempt to reuse If it is in reusable condition set it aside on a soft surface to prevent damage to the sealing edge 25 Us...

Page 8: ...place while it is being positioned inside the box bottom 4 While holding the vane switch in place set the box bottom on a flat surface with the open side facing down and the switch at 12 o clock Guide...

Page 9: ...er the stem of the poppet assembly so that it is seated securely at the base 11 Stand the valve body vertically with the male threaded inlet end facing down and positioned so that the lever faces di r...

Page 10: ...til it stops This will hold the pin securely in place to prevent it from falling out while installing the valve module into the box bottom 19 Lay the valve module assembly horizontally so that the adj...

Page 11: ...ment knob can be completely unscrewed and removed from the valve body do not attempt to assemble any further Disassemble as needed to cor rectly install the retaining pin Severe injury or death may ot...

Page 12: ...Thread the male fitting of the IP hose into the preferred low pressure port of the first stage and apply a torque wrench with 11 16 crow foot to tighten to 40 inch pounds 2 2 Connect an intermediate...

Page 13: ...low has stopped Release the knob of the adjustment tool to ensure that it no longer makes contact with the crown CAUTION Over adjustment of the crown will cause exces sive spring load in the second st...

Page 14: ...e intermediate pressure gauge 2 When the intermediate pressure gauge begins to drop below the intermediate pressure lockup the magnahelic gauge should indicate an opening effort of 6 of H2O to 1 0 of...

Page 15: ...ECTIVE BREATHING TEST 1 While the regulator is connected to a cylinder containing 3 000 psi and pressurized turn the second stage adjustment knob completely out counterclockwise to the full positive p...

Page 16: ...erly engaged with 2 Disassemble and inspect condi Poppet LP Seat Assy 27 tion of Poppet LP Seat Assy 3 Crown 21 incorrectly adjusted 3 Reset crown and perform Final lever 26 set too low Tuning Testing...

Page 17: ...blade screwdriver Crown removal installation N A 22mm wrench crow foot Hex nut removal installation N A 11 16 wrench crow foot IP hose fitting 1078 46 Circlip Retaining Ring Tool C clip retaining ring...

Page 18: ...Slight leak Knob turned in CW 1 2 3 4 turn None Intermediate pressure Inlet 2 500 3 000 100 psi 140 5 psi Intermediate pressure creep Inlet 2 500 3 000 100 psi 5 psi max between 5 to 15 seconds after...

Page 19: ...esh Water Rinse If tap water is extremely hard distilled water may be used to prevent any mineral residue Remove parts from the neutralizing bath and place directly into this rinse Agitate lightly and...

Page 20: ...7922 White distilled vinegar Acid bath for reuseable stainless Household grade 100 gr steel and brass parts Liquid dishwashing detergent Degreaser for brass and stainless steel parts Household grade d...

Page 21: ...Impulse Second Stage Service Repair Manual 19 1997 U S Divers Co Inc TECHNICIAN S NOTES...

Page 22: ...e Adjustment Switch 15 1094 38 Mouthpiece Comfo Bite Black 16 1049 13 Clamp Black 17 1078 11 Exhaust Tee Key Part Description Key Part Description 18 8601 37 C clip 19 1078 22 Exhaust Valve 20 8200 10...

Reviews: