U.S. Divers Impulse Service & Repair Manual Download Page 13

Impulse Second Stage Service & Repair Manual

11

© 1997 U.S. Divers Co., Inc.

and gently turn the knob until it can be felt that the adjustment
stem has mated into the slotted head of the crown.  Continue
to hold the knob inward, in order to prevent it from being
pressed outward by the internal air pressure.
a. If airflow cannot be heard, slowly turn the crown out

counter-clockwise only until a very slight leak is present.

b. If strong airflow beyond a slight leak is present, slowly turn

the crown clockwise in very small increments of adjust-
ment while simultaneously depressing the purge of the
second stage, and pause to listen after each adjustment until
only a slight leak remains.  It is important to adjust the
crown in this manner only until the airflow has stopped,
without over-adjusting.  When only a slight amount of
airflow is present, release the knob of the adjustment tool to
ensure that it no longer makes contact with the crown.

8.

When a slight leak has been established, turn the second stage
adjustment knob between 

1/2 - 3/4

 turn clockwise.  Purge the

second stage, and then listen closely to determine whether any
airflow can still be heard.
a. If airflow can still be heard, re-engage the inline adjustment

tool with the crown as described in step 7, and turn the
crown slightly in clockwise only until the airflow has
stopped.  Release the knob of the adjustment tool to ensure
that it no longer makes contact with the crown.

CAUTION

:  Over-adjustment of the crown will cause exces-

sive spring load in the second stage valve, and will severely
degrade the performance of the regulator.

9.

To test the setting of the crown, turn the second stage adjust-
ment knob completely out counter-clockwise to initiate a
slight flow of air, and then slowly turn it back in clockwise to
verify that the airflow has stopped completely before it has
been turned 

2

 turn.  If more than 

1/2

 turn is required to shut

off 

the airflow, it will be necessary to readjust the crown as

described in step 8a.

10. After turning the adjustment knob 

1/2

 turn clockwise to stop

the airflow, purge the second-stage regulator several times and
listen for any leaks.  Perform any follow-up adjustments as
needed at the source to eliminate the leakage.

NOTE:

  If leakage persists after performing the above proce-

dures, refer to Table 1, Troubleshooting, and disassemble as
required to remedy the problem.

11. Turn the valve of the air source completely shut, and purge the

second stage to depressurize the system.  Disconnect the in-
line adjustment tool from the second stage, and connect the
female fitting of the IP hose to the second stage inlet.  Apply a
torque wrench with 

11/16"

 crow-foot to tighten the IP hose

fitting to a torque measurement of 40 inch-lbs (

±

3).

12. Slide the hose protector(10) over the inlet connection of the IP

hose, and mate the index tab into the box top.

Summary of Contents for Impulse

Page 1: ...Impulse SecondStageRegulator P O Box 25018 3323 W Warner Ave Santa Ana CA 92799 5018 Copyright 1997 U S Divers Co Inc Doc No 1078 56 Authorized Aqua Lung Dealer SERVICE REPAIR MANUAL...

Page 2: ...Testing Procedures 10 Second Stage Air Flow Test 12 Second Stage Opening Effort Test 12 Second Stage Purge Flow Test 12 External Leak Test 12 Subjective Breathing Test 13 Table 1 Troubleshooting Guide...

Page 3: ...es outlined in the Impulse Owner s Manual GENERAL GUIDELINES 1 In order to correctly perform the procedures outlined in this manual it is important to follow each step exactly in the order given Read...

Page 4: ...tage with a stable intermediate pressure of 140 psi 5 with no open ports or hoses 2 Connect the first stage to a cylinder that is filled with 3 000 psi and open the cylinder valve to pressurize the re...

Page 5: ...mouthpiece 15 from the box bottom Inspect the mouth piece to ensure it is free of any tears or cuts that may cause leakage of water into the second stage or other discomfort Discard or set the mouthp...

Page 6: ...the washer 29 for any signs of wear or damage and discard if found 14 Remove and discard both O rings 30 31 and set the adjust ment knob aside to be cleaned separately in a mild acid bath white vineg...

Page 7: ...the polished sealing surface If damage is found discard the crown and do not attempt to reuse If it is in reusable condition set it aside on a soft surface to prevent damage to the sealing edge 25 Us...

Page 8: ...place while it is being positioned inside the box bottom 4 While holding the vane switch in place set the box bottom on a flat surface with the open side facing down and the switch at 12 o clock Guide...

Page 9: ...er the stem of the poppet assembly so that it is seated securely at the base 11 Stand the valve body vertically with the male threaded inlet end facing down and positioned so that the lever faces di r...

Page 10: ...til it stops This will hold the pin securely in place to prevent it from falling out while installing the valve module into the box bottom 19 Lay the valve module assembly horizontally so that the adj...

Page 11: ...ment knob can be completely unscrewed and removed from the valve body do not attempt to assemble any further Disassemble as needed to cor rectly install the retaining pin Severe injury or death may ot...

Page 12: ...Thread the male fitting of the IP hose into the preferred low pressure port of the first stage and apply a torque wrench with 11 16 crow foot to tighten to 40 inch pounds 2 2 Connect an intermediate...

Page 13: ...low has stopped Release the knob of the adjustment tool to ensure that it no longer makes contact with the crown CAUTION Over adjustment of the crown will cause exces sive spring load in the second st...

Page 14: ...e intermediate pressure gauge 2 When the intermediate pressure gauge begins to drop below the intermediate pressure lockup the magnahelic gauge should indicate an opening effort of 6 of H2O to 1 0 of...

Page 15: ...ECTIVE BREATHING TEST 1 While the regulator is connected to a cylinder containing 3 000 psi and pressurized turn the second stage adjustment knob completely out counterclockwise to the full positive p...

Page 16: ...erly engaged with 2 Disassemble and inspect condi Poppet LP Seat Assy 27 tion of Poppet LP Seat Assy 3 Crown 21 incorrectly adjusted 3 Reset crown and perform Final lever 26 set too low Tuning Testing...

Page 17: ...blade screwdriver Crown removal installation N A 22mm wrench crow foot Hex nut removal installation N A 11 16 wrench crow foot IP hose fitting 1078 46 Circlip Retaining Ring Tool C clip retaining ring...

Page 18: ...Slight leak Knob turned in CW 1 2 3 4 turn None Intermediate pressure Inlet 2 500 3 000 100 psi 140 5 psi Intermediate pressure creep Inlet 2 500 3 000 100 psi 5 psi max between 5 to 15 seconds after...

Page 19: ...esh Water Rinse If tap water is extremely hard distilled water may be used to prevent any mineral residue Remove parts from the neutralizing bath and place directly into this rinse Agitate lightly and...

Page 20: ...7922 White distilled vinegar Acid bath for reuseable stainless Household grade 100 gr steel and brass parts Liquid dishwashing detergent Degreaser for brass and stainless steel parts Household grade d...

Page 21: ...Impulse Second Stage Service Repair Manual 19 1997 U S Divers Co Inc TECHNICIAN S NOTES...

Page 22: ...e Adjustment Switch 15 1094 38 Mouthpiece Comfo Bite Black 16 1049 13 Clamp Black 17 1078 11 Exhaust Tee Key Part Description Key Part Description 18 8601 37 C clip 19 1078 22 Exhaust Valve 20 8200 10...

Reviews: