5
TABLE 1A: DIMENSIONAL DATA (SEE FIGURES 1A THRU 1D)
TABLE 1B: RATING DATA
Boiler Model
No.
Dimensions
See Figures 1A thru 1D
Water Content - Gallons
Heat Transfer
Surface Area -
Sq. Ft.
Approximate
Shipping Weight
(LB.)
"A"
"B"
"C"
Steam Boiler
Water
Boiler
V8H3
17-1/8"
9-1/8"
6"
10.3
12.8
15.88
542
V8H4
22-1/8"
11-5/8"
6"
12.4
15.7
22.92
634
V8H5
27-1/8"
14-1/8"
7"
14.6
18.5
29.96
726
V8H6
32-1/8"
16-5/8"
7"
16.7
21.4
37.00
818
V8H7
37-1/8"
19-1/8"
8"
18.8
24.2
44.04
910
V8H8
42-1/8"
21-5/8"
8"
20.9
27.1
51.08
1002
V8H9
47-1/8"
24-1/8"
8"
23.0
30.0
58.12
1094
NOTE: 1 Maximum working Pressure: Steam: 15 PSI; Water: 30 PSI Shipped From Factory (Std.),
40 PSI Optional, 50 PSI Optional
Boiler
Model No.
*
Burner Capacity
AHRI NET Ratings
AFUE %
(Thermal Effy.)
Minimum Chimney
Requirements
GPH
MBH
DOE Heating
Capacity MBH
Water
MBH
Steam
MBH
Steam
Sq. Ft. Steam Water
Round
In. Dia.
Rectangle
In. x In.
Height
Ft.
V8H3S
0.75
1.05
91
68
283
85.1
6
8 x 8
15
V8H3W
1.05
147
125
109
85.0
6
8 x 8
15
V8H4S
1.05
147
127
95
396
85.3
6
8 x 8
15
V8H4W
1.35
189
162
141
85.3
7
8 x 8
15
V8H5S
1.35
189
164
123
512
85.4
7
8 x 8
15
V8H5W
1.65
231
198
172
85.3
7
8 x 8
15
V8H6S
1.65
231
201
151
629
85.7
7
8 x 8
15
V8H6W
1.90
266
228
198
85.3
8
8 x 8
15
V8H7S
2.10
294
252
189
787
84.7
8
8 x 8
15
V8H7W
2.10
294
252
219
85.3
8
8 x 8
15
V8H8S
2.35
329
266
200
833
(81.4)
8
8 x 12
15
V8H8W
2.35
329
275
239
(82.0)
8
8 x 12
15
V8H9S
2.60
364
298
224
933
(82.3)
9
8 x 12
15
V8H9W
2.60
364
299
260
(82.3)
9
8 x 12
15
* Boiler Model Suffix: S=Steam, W=Water
SECTION I: PRODUCT DESCRIPTION, SPECIFICATION
AND DIMENSIONAL DATA
The V8H Series boiler is a cast iron oil-fired water boiler
designed for closed forced circulation heating systems or a
low pressure steam boiler designed for use in closed heating
steam systems. This boiler must be vented by natural draft
into a fireclay tile-lined masonry chimney or chimney
constructed from type L vent or a factory built chimney
that complies with the type HT requirements of UL03. An
adequate supply of air for combustion, ventilation and
dilution of flue gases must be available in the boiler room.
Water Boilers
The V8H Series water boiler uses an Intelligent Oil
Boiler Control (boiler control). The boiler control
replaces the traditional electronic aquastat and
circulator relays and adds energy saving thermal purge
features. Energy is saved by starting the circulator and
delaying the burner start when there is residual heat
available in the boiler. A Warm Start Intelligent Oil
Boiler Control (Warm Start Boiler Control) is included
with a tankless heater option to generate domestic hot
water.
Steam Boilers
The V8H Series steam boiler uses a L404F Pressure
Limit and Low Water Cut-off. This boiler has indirect
domestic water heater connections to generate domestic
hot water. Optionally, this boiler may include a L4006
Temperature Limit and a tankless heater to generate
domestic hot water.
Summary of Contents for PV8H7
Page 76: ...76 Bare Boiler Assembly Continued SECTION XVI Repair Parts continued ...
Page 78: ...78 Jacket Assembly SECTION XVI Repair Parts continued ...
Page 80: ...80 V8H3 Thru V8H9 Steam Boilers Trim and Controls SECTION XVI Repair Parts continued ...
Page 82: ...82 V8H3 Thru V8H9 Water Boilers Trim and Controls SECTION XVI Repair Parts continued ...
Page 84: ...84 Beckett AFG Burner SECTION XVI Repair Parts continued ...
Page 94: ...94 ...
Page 95: ...95 ...
Page 96: ...96 U S Boiler Company Inc P O Box 3020 Lancaster PA 17604 1 888 432 8887 www usboiler net ...