Opening the door with the key or the cylinder handle generates an event FORCED
ENTRY (if the door contact is connected).
Door time
If door sensor is open, corresponding access point goes into “Alarm” mode (refer to
“Alarm» mode below). Alarm is not invoked, if contact is opened during Door Time
interval. This interval starts when access is granted and lasts for the programmed
time or terminates on opening and subsequent closing of door contact.
Schedules
Date and time of valid access are indicated when setting user access rights.
Depending on modification, control panel stores up to 250 time zones. 250 week
schedules can be combined from these time zones. Moreover, control panel can
store up to 250 holidays, which happen once a year.
Time zones
Time zones are a part of schedule. This is a way to organize a range of days and
times and associate it with access levels.
Time zones are utilized by the application to validate, authorize, or perform various
functions based on schedules.
Downloading
Control panel is to be downloaded after all parameters are set
– modes of inputs,
outputs, access rights and others. During downloading parameters are rewritten into
access control panel.