http://u-prox.com
26
Connection
Wired or wireless computer network used for U-Prox IP100 communication to the
ACS server. Device setup is possible with using autoconfiguration or manually with a
PC using the software "Configurator":
Appropriate configuration provides:
Assigning of static or dynamic (DHCP) IP address to a device;
Working with two (primary and backup) IP or DNS (Domain Name Service)
of ACS server addresses;
Working on the Internet (service of remote branches) with the ability of
reserving paths to the Internet via the second router;
Use two Wi-Fi access points (primary and backup)
Panel works automatically after data upload from the ACS server. It processes
access rights for IDs passed grants or denies access and sent event reports to the
server.
Panel communicator operates in notification mode. If there is event (passage, input
violation) data transmission to ACS server is initiated.
Panel provides protection against arbitrary interference due to the encryption of data
with 256-bit key and against panel substitution supervising the unique serial number
of the device at its work in the network. It also provides supervision of the
communication channel by means of periodic test signals from the device.
Wired computer network (Ethernet)
Ethernet interface is used to connect components of the system (PC and panels) in
the network. Ethernet cable length without additional equipment can be up to 100
meters.
Use standard Ethernet cable, which involves four wires: TX , TX-, RX , RX- for
connection. Transfer rate is up to 100Mb / s.
Ehernet
clamps of
panel's
connector
Cable color
Clamps of
RJ-45
connector
Direct connection
(to the switch or router)
1
White-Yellow
1
2
Yellow
2
3
White-Green
3
4
Green
6