U-Line WINE CAPTAIN U-1115WCB-00 Service Manual Download Page 2

U-Line Service

PRODUCT LIABILITY POLICY

Field service technicians are authorized to make an initial assessment. If in the servicer’s judgment the damage is the result of a product defect, 
the product would be removed and returned to U-Line in an unaltered condition. The dealer would then be authorized to permanently replace 
the end-user’s product at no cost to the end-user. Please call U-Line immediately at 1-800-779-2547 to initiate the RA and product exchange 
process.

If in the servicer’s judgment the damage is the result of installation issues (water connection/drain, etc.), the consumer would be so notified and 
the correction would be made by the servicer or installer without requiring removal of the product. Any claim for damages should be directed 
to the original installer.

Any U-Line unit involved in an alleged property damage claim must remain 

unaltered and unrepaired

, for evaluation. No service or repairs 

should be performed on any unit suspected to be involved in a property damage situation. If a unit has been altered or repaired in the field prior 
to U-Line’s evaluation, any claim for damage may be declined.

If the unit in question is a U-Line CLR or CLRCO 

with a drain pump

, both the unit 

and

 the drain pump (regardless of the manufacturer) must 

be returned to U-Line Corporation.

To complete the damage claim process for the customer, please obtain the following and forward to U-Line at [email protected], fax 
to 1-414-354-5696 or mail to the address below.

Pictures of the unit, installation and any alleged property damage.

Inquire when the problem first appeared, any prior problems with the product and provide a brief description of the alleged damages.

To expedite the claim process, U-Line will need two damage repair estimates.

Reference the RA number and customer name when providing this information.

If a unit is returned to U-Line, this evaluation will take approximately ten business days. 

No field service company is authorized to 

perform this evaluation

. When a Return Authorization Number is issued, and the unit has been boxed in a U-Line carton, U-Line should be 

contacted and then will make arrangements for shipping, or designate a truck line to have the unit shipped freight collect.

If U-Line’s evaluation finds the unit, (or U-Line P60 pump) to be defective, causing the property damage, the damage claim will be reviewed by 
the U-Line Customer Assurance Department.

If U-Line’s evaluation finds the unit not to be defective, does not repeat a failure or does not leak any water from the U-Line unit or U-Line P60 
pump, all claims for damage will be declined.

When a product evaluation is needed, it is the customer’s responsibility to assure that the unit is returned for evaluation. If the customer fails to 
do so, or has the unit repaired in the field prior to U-Line’s evaluation, any claim for damage will be declined.

8900 N. 55th St. • P.O. Box 245040

Milwaukee, WI 53224-9540 U.S.A.

1-414-354-0300 • Fax: 1-414-354-7905

Website: u-line.com

Leaders In Quality Undercounter Refrigeration

Summary of Contents for WINE CAPTAIN U-1115WCB-00

Page 1: ...15RB 00 U ADA24RB 13 U 1115WCB 02 U 1175BEVSS 02 U 1115RS 00 U ADA24RGLB 13 U 1115WCS 00 U 1175BEVSS 13 U 1115RS 01 U ADA24RGLS 13 U 1115WCS 02 U 1175BEVSS 15 U 1175RB 00 U ADA24RGLS 15 U 1115WCS 09 U...

Page 2: ...onlineservice U Line com fax to 1 414 354 5696 or mail to the address below Pictures of the unit installation and any alleged property damage Inquire when the problem first appeared any prior problem...

Page 3: ...2 Reversing the Door 12 Maintenance Lightbulb Replacement 14 Leveling 14 Removing and Installing Grille 14 Removing and Installing Interior Shelves 14 Wire Shelf Removal Installation 15 Removing and I...

Page 4: ...not easily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round...

Page 5: ...ight Hand Hinge GLASS BLACK WINE RACKS YES U 1115WCS 02 230V Right Hand Hinge GLASS STAINLESS WINE RACKS YES U 1115WCS 09 230V Right Hand Hinge GLASS STAINLESS WINE RACKS YES U 1175WCB 00 120V Right H...

Page 6: ...rately Included in labor are freon and recovery charges all other parts are handled by the parts department We require that some parts be returned to us so we may return them to our vendor It will be...

Page 7: ...Number Part Number Part Description and in some cases Color or Voltage All warranty parts will be shipped at no charge as long as warranty status has been confirmed If we require that a part be retur...

Page 8: ...nt grille or condenser are obstructed Normal Operating Sounds All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal worki...

Page 9: ...360 1 38 U 1175RW 13 49 3 45 360 1 38 U 1115WCB 00 77 4 45 360 1 50 U 1115WCB 02 78 4 45 360 1 50 U 1115WCS 00 77 4 45 360 1 50 U 1115WCS 02 78 4 45 360 1 50 U 1115WCS 09 78 4 45 360 1 50 U 1175WCB 00...

Page 10: ...rn OFF and door operated lighting control will resume 3 To exit the timed lighting control before the end of the four hour period repeat Step 1 Blackout Sabbath Mode The interior of the cabinet and co...

Page 11: ...ese temperatures are approximate and calibrated for a cabinet in normal ambient temperatures with some product load Checking a completely unloaded cabinet may result in other temperatures or inaccurat...

Page 12: ...e number of defrosts that have occurred in the past 24 hours 5 Compressor runtime based on last cycle This will show the number of minutes the compressor has run in the prior cycle or current cycle if...

Page 13: ...e d o C r o r r E s t n e m g e s D E L l l a t h g i L 1 0 n e p o r o t s i m r e h T 1 E s u t a t S r o t s i m r e h T 2 0 d e t r o h s r o t s i m r e h T 2 E g o L r o r r E 3 0 s e t u n i m...

Page 14: ...Cool units are available with solid or glass doors Evaporator Fan Replacement Remove the back panel Unplug the evaporator fan motor Remove the shelves Remove 2 screws at the top of the evaporator cove...

Page 15: ...doors without locks are field reversible See the table at the front of this book for a summary of units that are reversible Stainless steel models without glass doors must be ordered right or left ha...

Page 16: ...racket 5 Remove door actuator 4 from door Be sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was remove...

Page 17: ...For Models with adjustable leveling feet 1 Use a level to check the levelness of the unit from front to back and from side to side Place the level along top edge and side edge as shown 1 2 If the uni...

Page 18: ...nderside of the shelves Wire Shelf Removal Installation For ADA models equipped with wire racks reposition the shelves as follows 1 Remove shelf retention clip 2 Pull shelf out about 6 1 until back of...

Page 19: ...y bottles stored on the rack 2 Grasp the end of the rack and gently slide it out until it stops 3 Press the left rack release lever down At the same time lift the matching right rack release lever up...

Page 20: ...ne s warranty is 90 days for door or drawer adjustments Has the door or drawers been left open Is the condenser clean U Line s warranty does not cover cleaning the condenser Is the unit behind closed...

Page 21: ...e suction line to the compressor inlet The compressor takes the low pressure vapor and compresses it increasing both pressure and temperature The hot high pressure gas is pumped out the discharge line...

Page 22: ...normal Partial Restriction Somewhat lower than normal in vacuum Warm near room temperature Very hot Top passes warm lower passes cool near room temperature due to liquid Room temperature cool or cold...

Page 23: ...rmally The display will show ER Reed Switch A reed switch is mounted to the underside of each cabinet and a magnet is mounted to the door When the door is closed magnetic force pulls the reed to its c...

Page 24: ...remedies Most often this will resolve the problem without the need to call for service If Service is Required If you do not understand a troubleshooting remedy or your product needs service contact U...

Page 25: ...inless to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Interior Cleaning Disconnect power to the un...

Page 26: ...fore operating replace all panels Failure to do so may result in death or electrical shock NOTICE If the ambient temperature is expected to drop below 50 F turn off and unplug unit and drain all water...

Page 27: ...s The U Line brand offers products in the 1000 Series 2000 Series and the Modular 3000 Series The 1000 Series offers a more targeted priced product with appropriate features while the 2000 Series offe...