Prepare Site
3
4 Prepare Site
Your U-Line product has been designed for either free-standing or
built-in installation. When built-in, your unit does not require
additional air space for top, sides, or rear. However, the front grille
must NOT be obstructed and clearance is required for an
electrical connection in the rear.
IMPORTANT
IMPORTANT
• Unit can NOT be installed behind a closed cabinet door.
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.
See below for recommended receptacle location & cut out
dimensions
2275DWRC Series
Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease
in installation and removal of the unit. 24" is the cabinet depth in
most installations.
34-1/4"
to
35-1/8"
24-1/4"
24"
1-1/2"
7"
C2275DWR Series
Follow the cut-out drawing The 24-1/4" width allows 1/4" for ease
in installation and removal of the unit. 24" is the cabinet depth in
most installations.
2275DWRW Series
Follow the cut-out drawing The 24-1/4" width allows 1/4" for ease
in installation and removal of the unit. 24" is the cabinet depth in
most installations.
34-1/4"
to
35-1/8"
24-1/4"
24"
1-1/2"
7"
34-1/4"
to
35-1/8"
24-1/4"
24"
1-1/2"
7"