USER GUIDE
System Diagnosis Guide
Figure 18: Parameter Details Display
Parameter List (factory settings)
Parameter
Description
5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
ADR
serial address
[num]
1
1
1
1
EVO
alarm intervention
super-parameter
[num]
0
0
0
0
IS1
probes and door
input configuration
super-parameter
[num]
155
155
155
155
IS2
digital input
configuration
super-parameter
[num]
8
8
8
8
IS3
not used
0
0
0
0
OS1
additional output
super-parameter
[num]
0
0
0
0
OS2
additional output
super-parameter
[num]
0
0
0
0
FOP
fans mode super-
parameter [num]
131
131
131
135
DOP
defrost mode
super-parameter
[num]
7
7
7
5
ALH
upper temperature
alarm limit [°C/°F]
50
50
50
50
ALL
lower temperature
alarm limit [°C/°F]
14
14
14
14
ALD
temperature alarm
delay [min]
60
60
60
60
ADS
temperature alarm
delay after start
[min]
180
180
180
180
ADF
temperature alarm
delay after defrost
[min]
120
120
120
120
HYH
upper differential
cooling action
[°C/°F]
4
4
4
4
HYL
lower differential
cooling action
[°C/°F]
0
0
0
0
MNT
number of trays of
blast chiller [num]
15
15
15
15
Parameter
Description
5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
DAC
compressor stop
delay [sec]
3
3
3
3
ADL
minimum time of
stop compressor
[sec]
60
60
60
60
ASS
start compressor
delay at power on
[sec]
30
30
30
30
CON
compressor on
time in probe
faulty [min]
5
5
5
5
COF
compressor off
time in probe
faulty [min]
10
10
10
10
CPH
not used
90
90
90
90
FAS
evaporator fan set
point [°C/°F]
50
50
50
50
HFF
differential of fan
set point [°C/°F]
9
9
9
9
FAD
delay of fan start
in evaporator
probe faulty [sec]
5
5
5
5
FSD
stop evaporator
fan temperature in
defrost [°C/°F]
14
14
14
14
LBT
minumum
evaporator
temperature
related to set point
[°C/°F]
50
50
50
50
EDT
choking evaporator
fan temperature
range [°C/°F]
59
59
59
59
FEN
minimum
evaporator fan
speed % [num]
25
25
25
25
FEX
maximum
evaporator fan
speed % [num]
95
95
95
95
DOO
max open door
time before door
alarm [sec]
60
60
60
60
FCE
condenser fan set
point [°C/°F]
77
77
77
77
HYF
upper differential
condenser fan
action [°C/°F]
9
9
9
9
MCT
max condenser
temperature
[°C/°F]
131
131
131
131
DCN
dirty condenser
threshold [°C/°F]
0
0
0
0
GAS
low refrigerant
amount alert
threshold [°C/°F]
0
0
0
0
DCR
differential for
restarting blast
chiller after
high condenser
temperature
[°C/°F]
18
18
18
18
RMT
stop time during
high condenser
temperature [sec]
180
180
180
180
60