Parameter
Description
Factory
Value
P68
P64, P65, P66 and P67 differential
2
P69
storage operation start-up temperature
alarm delay
0
P70
temperature alarm delay
0
P71
enable printing 1 = YES
0
P72
print interval
5
P73
HACCP alarm list deletion 1 = YES
0
P74
Baudrate 0=2400
1=4800
2=9600
3=19200
2
P75
Bit polarity 0=no polarity 1=even 2=odd
2
P76
Board address
1
All GBF units from 5 to 18 Shelves (Hot gas Defrost)
Parameter
Description
Factory
Value
P0
unit of temperature measurement
0 = °F
1 = °C
1
P1
cabinet probe offset
2
P2
evaporator probe offset
0
P3
needle probe offset
0
P4
operational setpoint during the second
hard chill step; also, operational
setpoint during normal chilling (with
reference to the cabinet probe)
0
P5
operational setpoint during freezing
(with reference to the cabinet probe)
-40
P6
operational setpoint during the first hard
chill step (with reference to the cabinet
probe)
-20
P7
operational setpoint during post-chill
storage (with reference to the cabinet
probe)
3
P8
operational setpoint during post-freeze
storage (with reference to the cabinet
probe)
-20
P9
P4, P5, P6, P7 and P8 differential
1
P10
set temperature chill end temperature
(with reference to the needle probe)
3
P11
set temperature freeze end temperature
(with reference to the needle probe)
-18
P12
temperature at which the hard chill
switches from the first step to the
second (with reference to the needle
probe)
20
P13
temperature above which it is not
possible to start a set- temperature
operational cycle (with reference to the
needle probe)
99
P14
needle probe and the cabinet
temperature for verification of correct
needle probe insertion
0 = the test will not be performed
0
P15
duration of the second test to check
correct needle probe insertion; see also
P14
60
Parameter
Description
Factory
Value
P16
maximum set temperature chill
duration; also timed chill duration
90
P17
maximum set temperature freeze
duration; also timed freeze duration
240
P18
first hard timed chill step duration
45
P19
compressor delay from device power on
(from restoration of power)
0
P20
minimum elapsed time period between
two consecutive compressor start-up
operations
0
P21
minimum compressor shut-down time
0
P22
defrost type
0 = electric (defrost on relay)
1 = hot gas (defrost compressor and
relay on)
2 = air (evaporator fan on)
1
P23
defrost end temperature (with reference
to the evaporator probe)
8
P24
maximum defrost duration
10
P25
defrost interval during storage; see also
P26
0 = intermittent defrosting will never
be activated (only the first will be
activated)
6
P26
first defrost delay from start of storage;
see also P25
1
P27
defrosting at start of chilling and
freezing 1 = YES
0
P28
drip-drain duration
2
P29
resetting of compressor protections at
start of defrosting (only if P22 = 1)
1 = YES
0
P30
elapsed time between the defrost
request and switching on the
compressor (only if P22 = 1 and
providing that the compressor is off
when the defrost is requested); see P31
(7) (8)also
30
P31
elapsed time between the defrost
request and activation of the solenoid
valve (only if P22 = 1 and on condition
that the compressor is off when
defrosting is requested); see also P30
0
P32
temperature above which the evaporator
fan is switched off during storage (with
reference to the evaporator probe)
3
P33
P32 differential
1
P34
evaporator fan activity during defrosting
(only if P22 = 0 or 1)
0 = on
1 = off
0
P35
evaporator stop time after dripping
3
P36
temperature above which the evaporator
fan is switched off (with reference to the
cabinet probe)
90
P37
effect caused by activation of microport
input on evaporator fan
0 = no effect
1 = the evaporator fan will be switched
off
1
50