background image

QUICK START GUIDE

9

u-line.com

General Installation

LEVELING INFORMATION

1. Use a level to 

confirm the unit is 
level. Level should 
be placed along top 
edge and side edge 
as shown.

2. If the unit is not level, adjust the legs on the corners of 

the unit as necessary.

3. Confirm the unit is level after each adjustment and 

repeat the previous steps until the unit is level.

INSTALLATION TIP

If the room floor is higher than the floor in the cutout 
opening, adjust the rear legs to achieve a total unit rear 
height of 1/8" (3 mm) less than the opening’s rear height. 
Shorten the unit height in the front by adjusting the front 
legs. This allows the unit to be gently tipped into the 
opening. Readjust the front legs to level the unit after it is 
correctly positioned in the opening.

INSTALLATION

1. Plug in the power/electrical cord.

2. Gently push the unit into position. Be careful not to 

entangle the cord or water and drain lines.

3. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" (3 mm) below 
the counter top.

4. Install the anti-tip bracket.

5. Remove interior packing material and wipe out the 

inside of the unit with a clean, water-dampened cloth.

Integrated Panel Installation

1. Fully open door/drawer.

2. Starting at corner, pull 

gasket away from door/
drawer.

3. Continue to pull gasket 

free from gasket channel.

4. Upon removal, lay gasket 

down on a flat surface.

5. Partially loosen the 3 screws, securing the top hinge to 

the cabinet.

6. Align the panel with the outside edge (opposite the 

hinge) and high enough to align with the highest point 
in the door/drawer.

7. Insert panel underneath top hinge and apply upward 

pressure while bringing the lower portion of the panel 
flush to the door inside the lower hinge. The panel will 
fit snuggly

1

Turn to Adjust

Summary of Contents for U-CLR1215S-40B

Page 1: ...QUICK START GUIDE 1000 Series CLR1215 115 V 60 Hz...

Page 2: ...to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all availab...

Page 3: ...1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 7 Drain 8 Door Swing 9 General Installation 9 Integrated Panel Installation 11 Control Operation 11 First Us...

Page 4: ...view detailed User Guides for all U Line products Clear Ice U CLR1215S 00B U CLR1215S 40B U CLR1215INT 00B U CLR1215INT 40B U CLR1215B 00B U CLR1215B 40B U CLR1215W 00B U CLR1215W 40B Outdoor Series U...

Page 5: ...igned to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best perform...

Page 6: ...ces and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup INDOOR MODELS PREPARE PLUMBING Please use the braided s...

Page 7: ...r harm flooding or void the product warranty CAUTION Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn off water supply and disconnect electrical supply to pr...

Page 8: ...s product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Conne...

Page 9: ...Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break...

Page 10: ...be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all co...

Page 11: ...or Swing Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle...

Page 12: ...cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The u...

Page 13: ...ct depth in order to avoid splits in the wood when hardwood is installed 11 Locate 6 of the 6x 1 1 4 32 mm screws provided with your unit 12 Using a Phillips screwdriver place one screw into each of t...

Page 14: ...on to stabilize for 24 hours before rechecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice...

Page 15: ...ur clear ice machine is pre set to produce ice between the optimal dimensions illustrated below Ice thickness adjustments are made using the control panel as follows 1 To enter the thickness adjustmen...

Page 16: ...nty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and ser...

Page 17: ...y come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than...