u-line.com
17
General Information
Set Points
The Set points menu contains options to modify both the Zone and
Evap set points. Changes to the zone set point will be reflected on
the main screen. Changes to the evap set point alter the temperature
the evaporator needs to meet during a defrost cycle.
To access Set Points
1. Use Down
to select “Set Points”.
2. Press Select
.
3. Use Up
and Down
to scroll through available set points.
To change set point
4. Press Select
, the selected set point will begin to flash.
5. Use Up
or Down
to modify the value.
6. Press Select
to confirm setting.
To exit the Set Points menu use Up
to select “Return to Menu”
and press Select
to confirm.
Factory Default
Factory Default will restore all settings to their factory default.
To access Factory Default
1. Use Down
to select “Factory Default”.
2. Press Select
.
To restore settings to their factory default
3. Use Down
to select “Restore?” and press Select
.
4. “Restore?” will change to “Restoring...” while settings are
restored. When restoration is complete, “Restoring...” will return
to “Restore”.
To exit Factory Default use Up
to select “Return to Menu” and
press Select
to confirm.
Re-Select Model
NOTICE
Before altering model selection, U-Line customer service
must be notified. Failure to notify customer service will
result in voiding of the manufacturer warranty. Call U-Line
Customer Service for assistance.
Re-Select Model allows the unit’s model configuration to be modified.
Changing the unit’s model completely reprograms available zones,
relay assignments, dc output assignments, etc.
To access Re-Select Model
1. Use Down
to select “Re-Select Model”.
2. Press Select
.
To alter model setting
3. Use Down
to select “Model=” and press Select
. “Model”
will begin to flash.
4. Press Up
or Down
to scroll through each available model.
5. Press Select
to confirm.
To exit Re-Select Model use Up
to select “Return to Menu” and
press Select
to confirm.
Fan Delay
The Fan Delay menu option allows the modification of fan run times
during and after a cooling cycle. In order to allow time for the
evaporator to properly cool, the evaporator fan is delayed from
starting with the cooling cycle for a given amount of time. In order to
remove as much warmth as possible from the cabinet, the evaporator
fan will continue to run at the end of the cooling cycle for a given
amount of time.
Fan Delay On =
“Fan Delay On” is the amount of time in minutes the fan will be
delayed from starting from the beginning of a cooling cycle.
Up
Select
Down
RETURN TO MENU
SET POINTS
ZONE = 38°F
EVAP = 42°F
Up
Select
Down
RETURN TO MENU
FACTORY DEFAULT
RESTORE?
Up
Select
Down
RETURN TO MENU
RE-SELECT MODEL #
3018R
Up
Select
Down
RETURN TO MENU
FAN DELAY
FAN DELAY ON = 1
FAN DELAY OFF = 2