USER GUIDE
Control Operation - Service 3
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
To access All Errors follow the steps below.
1. Press to select “All Errors”.
2. Press .
3. Press and to scroll through available
information.
To clear the error log press to select “Clear Errors” and
press
to
confirm.
To exit the Actual Temps menu press to select “Return
to Menu” and press to confirm.
Relay Status
Relay status displays the current state of each relay. While
all available relays are displayed, only a portion are used.
NOTE: The Cond (Condenser Fan) will switch state with
the compressor relay, however the condenser fan is
actually powered through a DC output. Condenser fan
status can be viewed through the “Output” service menu
option.
To access Relay Status
1. Use to select “Relay Status”.
2. Press .
3. Press and to scroll through available
information.
To exit the Relay Status simply press to exit.
ID
Description
Availability
Mull
Mullion Heater
Not Used
Pump
Circulation Pump
Used
Wate
Water Valve
Used
Harv
Harvest
Used
Cond
Condenser Fan
Used
Comp
Compressor
Used
Up
Select
Down
RETURN TO MENU
RELAY STATUS
MULL COND DEF LVLV
OFF OFF OFF OFF