PAGE 6 OF 21
0915 IH-2030
REPLACE IGNITER (CONTINUED)
4. Pull cable out. (See Figure 9)
5. Untie and remove ground strap. (See Figure 10)
6. Lift out trigger assembly. (See Figure 11)
Figure 9
Figure 10
Figure 11
CLEAN OR REPLACE ORIFICE
IMPORTANT! The orifice consists of 6 slender,
thin-walled tubes that are easily bent or
damaged. Once bent or damaged, gun
performance is seriously impaired. Perform
the following procedure with EXTREME CARE.
1. Remove 5 mounting screws and remove right side of
housing. (See Figure 12)
2. Remove the 3 screws holding the pump.
(See Figure 13)
3. Remove pump by sliding it away from the orifice, then
lift it out. (See Figure 13)
CAUTION! Lifting the pump before sliding it away
will damage the orifice tubes.
4. Unscrew the orifice. (See Figure 14)
5. Use a .6mm drill bit to clean out each orifice.
(See Figure 15)
Figure 12
Figure 13
Figure 14
Figure 15
CLEANING AND MAINTENANCE CONTINUED