background image

02/2005

9

www.U-LineService.com

SP18 Ice Maker

Leveling Information

IMPORTANT

It is extremely important that the unit sits on a level 
surface, as it does not have feet levelers. If it is not level, 
the ice mold will not fill evenly.

Use a level to check 
the levelness of the 
unit from front to 
back and from side 
to side. Level 
should be placed 
along top edge 
and side edge as 
shown (see 

Figure 

19

). Go on to 

8 Install the Unit

.

Installation of the SP18

1. Open the water supply valve in the main water source.

2. Plug in the power cord.

3. Gently push the unit into position. Be careful not to 

kink the water supply line or entangle the electrical 
cord. 

4. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments.

5. Secure the flange to the frame structure using the four 

holes in the flange. The type of fasteners will depend 
on the structure you are mounting the flange to.

Installation Troubleshooting

Problem

Q:

Water is leaking under the unit.

Solution

A:

A water leak under the unit is most likely caused by a bad 
connection in the water supply line. Make sure the water 
line’s brass fitting is screwed tight to its valve and 
threaded correctly. Make sure that plumbers tape was 
NOT used; if it was remove all traces before reinstalling.

7 Level the Unit

Check

Level

Figure 19

8 Install the Unit

Summary of Contents for Origins SP18

Page 1: ...one 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 SP18 Ice Maker for Marine or Recreational Vehicl...

Page 2: ...antial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a grounded three pron...

Page 3: ...unction You have received a carton containing your SP18 Ice Maker with a package inside containing a User Manual a Product Registration Card and water connection parts Complete and mail the Product Re...

Page 4: ...nter depth in most installations 26 5 16 depth includes the door handle and water line connection see Figure 2 IMPORTANT It is extremely important that the unit sits on a level surface as it does not...

Page 5: ...ews on either side 5 Install hinge on opposite side bottom of cabinet See Figure 8 Replace nut on back side where installed Align hinge outer edge with cabinet before tightening screws 6 Relocate plas...

Page 6: ...el pin in door engages the closer in the assembly then tighten screws on travel pin assembly securely See Figure 13 Other Site Requirements Power Supply The unit requires a grounded and polarized 110...

Page 7: ...local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follow recommendations and instructions may result in damage and or harm WARNING To prevent accide...

Page 8: ...17 This will also safeguard against kinking the line 5 Go on to 6 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requi...

Page 9: ...osition Be careful not to kink the water supply line or entangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments 5 Secure the flange to t...

Page 10: ...n temperature for ice storage IMPORTANT It is possible that dirt or scale will dislodge in the water line Always throw away all ice cubes made during the first twenty four 24 hours of operation Start...

Page 11: ...es U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact th...