PAGE 7 OF 21
0616 IH-1604
ERROR CODES
Consult the chart below if the display shows an error code and the red LED flashes. Try the appropriate action for the
problem, then press the STOP/RESET button to resume operation.
DISPLAY CODE
ISSUE
ACTION
E1
Cover open.
Make sure covers are closed.
E2
Jam/end of roll.
In case of jam, open belt cover and remove jammed film carefully.
E3
Temp. too high.
Contact Uline Customer Service at 1-800-295-5510.
E4
Temp. too low.
Contact Uline Customer Service at 1-800-295-5510.
E5
Temp. not rising.
Contact Uline Customer Service at 1-800-295-5510.
E6
No roll detected.
Press STOP/RESET. This may clear the error. If not, display will show
"
sty
"
(standby). Advance
the film slowly at the front of the machine so the film roll rotates. The display should show the
seal temperature and then
"
rdy
"
(ready). If the error can't be cleared, contact Uline Customer
Service at 1-800-295-5510 for assistance.
TROUBLESHOOTING
OPERATING ISSUE
CAUSES
RECOMMENDATIONS
No power to Mini Pak'r™
machine.
Power cord is unplugged.
Circuit breaker OFF.
Power Switch OFF.
Main fuse is blown.
Belt cover(s) open.
Plug power cord into Mini Pak'r™ machine and outlet.
Turn circuit breaker ON at electrical panel.
Turn power switch ON.
Replace main fuse.
Tighten belt cover screw with screwdriver.
Film won't advance.
Film roll installed backwards.
Using incompatible film.
Turn film roll around. (See page 2)
Install compatible roll.
Air cushions do not hold air.
Air fill tube not inside film.
Air pump not working.
Seals leaking.
Too much air fill.
Reload film onto air fill tube. (See page 2)
Contact Uline Customer Service at 1-800-295-5510.
Adjust seal temperature. (See page 5)
Reduce air fill. (See page 5)
Film jams frequently.
Blade is dull.
Drive belts are worn.
Replace blade. (See page 6)
Replace both drive belts. (See page 6)
Machine won't stop
automatically.
Length control set to continuous.
Press (+) or (–) length control buttons to set desired
length of air cushion production. (See page 4)
ERRORS AND TROUBLESHOOTING
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
1-800-295-5510
uline.com