background image

PAGE 3 OF 8 

0422 IH-9884

OPERATION

CALIBRATION

1.  Press and hold MENU-CAL until 

MENU

 is displayed. 

When button is released, the display will show 

CAL

.

2.  Press YES to accept; 

SPAN

 will be shown. Press YES 

again to begin span calibration. 

3. 

 --C--

 will blink while zero reading is stored. The 

display will show the calibration weight value. Place 

the specified weight value on the pan. 

--C--

  will 

blink while the reading is stored. 

4.  The scale will return to the previous application 

mode and is ready for use.

WEIGH MODE

1.  Press and hold MODE until 

WEIGH

 is displayed.

2.  If required, place an empty container on the pan 

and press TARE.

3.  Add material to the pan or container. The display 

will show the weight of the material.

PARTS COUNTING MODE

NOTE: This mode counts large numbers of items 
based on the weight of a reference count.

1.  Place an empty container on the pan and press 

TARE.

2.  Press and hold MODE until 

COUNT

 is displayed.  

CLr.APU

 (Clear Average Piece Weight) will then 

display.

3.  Press NO to use the stored Average Piece Weight 

(APW) or press YES to establish a new APW.

NOTE: If choosing NO to use stored APW, skip  
to step 6.

NOTE: If choosing YES to set a new APW, 

continue to step 4.

NOTE: Press FUNCTION to view the current APW.

NOTE: To clear the stored APW, press and hold 
MODE until 

COUNT

 is displayed. Press YES when 

CLr.APU

 is displayed.

4.  After pressing yes, the scale will then display the 

stored sample size. Press NO or BACK to toggle the 

choices 5, 10, 20, 50 or 100.

5.  Put the indicated number of pieces on the pan. 

Press YES to calculate the APW. The display will show 

the piece count.

6.  Add additional pieces until the desired count is 

reached.

CHECKWEIGH MODE

NOTE: This mode sets low and high weight limits 
for portion control processes.

1.  Press and hold MODE until 

CHECK

 is displayed.  

CLr.rEF

 (Clear References) will then display.

2.  Press NO to use the stored reference weight limits or 

press YES to establish new reference values.  

(Skip to step 5)

NOTE: If choosing NO to use stored reference 
wight limits, skip to step 5.

NOTE: If choosing YES to set new reference 
weight limits, Continue to step 3.

NOTE: Press FUNCTION to view low and high 
reference weight limits.

To clear the stored reference values, press and 

hold MODE until 

CHECK

 is displayed. Press YES 

when 

CLr.rEF

 is displayed.

3.  The balance will then display 

SET. Lo

. Press YES to 

view the "Low" limit value. Press YES to accept or 
NO to edit the "Low" limit value. The stored value 

displays with the first digit highlighted

 000.000

 kg. 

Repeatedly press NO until the desired number 

appears. Press YES to accept and highlight the next 

digit. Repeat until all the digits are correct. Press YES 

to accept the   

 "Low" limit value; 

SET. HI

 will be displayed.

4.  Repeat steps 1-3 to accept or edit the "High" value.

5.  Place sample material on the pan. The "Accept" 

indicator will show that the sample weight is within 

the acceptable range.

Summary of Contents for H-9884

Page 1: ...e on Long Press when on Turns the scale off Short Press in Menu Selects accepts displayed setting Long Press Toggles through active units Short Press in Menu Toggles through available settings Short P...

Page 2: ...Disconnect from power supply when cleaning Service should only be performed by authorized personnel SETUP TRANSPORTATION LOCK 1 Rotate the pointer on the transportation lock to the unlocked position S...

Page 3: ...4 After pressing yes the scale will then display the stored sample size Press NO or BACK to toggle the choices 5 10 20 50 or 100 5 Put the indicated number of pieces on the pan Press YES to calculate...

Page 4: ...on procedure zero and span A span calibration is important when initially setting up the scale Lin LIN yes no Initiates a linearity calibration procedure zero mid point and span SETUP SUB MENU Back Li...

Page 5: ...he menu must be turned on to be active NOTE Available units and modes vary by model and local regulations SECURITY SWITCH Menu Lock switch may be used to limit changes to the user menu See Figure 4 Th...

Page 6: ...nge exceeded Clear pan check shipping lock setting Err 8 2 LoAd Power on zero under range Install pan check shipping lock setting Err 8 3 LoAd Overload Load exceeds scale maximum capacity Err 8 4 LoAd...

Page 7: ...des Weighing Parts Counting Checkweighing Power Requirement AC adapter included or four C batteries not included Typical Battery Life 270 hours 200 hours 270 hours Specified Temperature Range 50 F to...

Page 8: ...0 0001 21 574 x 0 001 Ounce oz 7 7600 x 0 0005 77 6025 x 0 0005 77 600 x 0 005 Ounce Troy ozt 7 0730 x 0 0005 70 7315 x 0 0005 70 730 x 0 005 Pennyweight dwt 141 46 x 0 01 1 414 63 x 0 01 1 414 6 x 0...

Reviews: