background image

PAGE 2 OF 9 

0222 IH-9774

ASSEMBLY

IMPORTANT! This pump is made out of PTFE, 
PVDF and 304 stainless steel. Use chemicals 

compatible with these materials and follow 
OSHA guidelines when using this pump, 

including proper grounding and protective 
gear as required. For a full list of materials and 

compatible chemicals, see uline.com. Unit not 
UL or FM approved.

1.  Attach handle to pump cover using long screw (10) 

and attach to piston rod using short screw (20). 

Hand tighten until all screws are attached.  

(See Figure 2)

NOTE: Piston rod is inside pump. Loosen top nut 
to pull piston rod up.

NOTE: You may switch screw position on the 
handle to adjust the flow. (See Operation on 
page 3)

2.  Apply included sealant tape to threading on pump 

cover. (See Figure 3)

3.  Put spout (9) through screw nut (5) and tighten onto 

pump cover. Attach barb spout (26) as needed. 

(See Figure 4) 

4.  Apply included sealant tape to threading on upper 

extend tube (4). (See Figure 5)

Figure 4

26

10

Figure 2

20

Figure 3

Figure 5

4

9

5

Summary of Contents for H-9774

Page 1: ...TOOLS NEEDED Flathead Screwdriver 2 9 5 8 6 4 3 7 22 22 24 13 11 15 14 18 12 20 20 21 12 12 19 17 16 25 12 26 23 10 1 DESCRIPTION QTY 1 Extend Tube 1 2 Bushing 1 3 Extend Tube Piston 1 4 Upper Extend...

Page 2: ...ng long screw 10 and attach to piston rod using short screw 20 Hand tighten until all screws are attached See Figure 2 NOTE Piston rod is inside pump Loosen top nut to pull piston rod up NOTE You may...

Page 3: ...tube is at desired depth in the drum ASSEMBLY CONTINUED OPERATION Figure 6 4 1 800 295 5510 uline com A B C D Figure 8 Pump is now ready for operation Liquids should begin flowing on the second or thi...

Page 4: ...ps HERRAMIENTAS NECESARIAS Desarmador Plano 2 9 5 8 6 4 3 7 22 22 24 13 11 15 14 18 12 20 20 21 12 12 19 17 16 25 12 26 23 10 1 DESCRIPCI N CANT 1 Tubo de Extensi n 1 2 Casquillo 1 3 Pist n de Tubo de...

Page 5: ...Apri telos con la mano hasta que todos los tornillos est n fijos Vea Diagrama 2 NOTA La varilla del pist n est adentro de la bomba Afloje la tuerca superior para poder elevar la varilla del pist n NO...

Page 6: ...ea Diagrama 7 NOTA Aseg rese de fijar la bomba y el tubo de succi n ensamblado de modo que este quede a la profundidad deseada en el tambo La bomba ya est lista para usar Los l quidos deben comenzar a...

Page 7: ...Viscosit maximale 2 000 pascal seconde OUTILS REQUIS Tournevis t te plate 2 9 5 8 6 4 3 7 22 22 24 13 11 15 14 18 12 20 20 21 12 12 19 17 16 25 12 26 23 10 1 DESCRIPTION QT 1 Tube rallonge 1 2 Bague...

Page 8: ...gn e au couvercle de la pompe avec une vis longue 10 et fixez la la tige de piston avec une vis courte 20 Effectuez un serrage manuel jusqu ce que toutes les vis soient fix es Voir Figure 2 REMARQUE L...

Page 9: ...pond un d bit de 6 oz REMARQUE Le trou B correspond un d bit de 8 oz REMARQUE Le trou C correspond un d bit de 10 oz REMARQUE Le trou D correspond un d bit de 12 oz Figure 7 Figure 6 4 6 5 Vissez le t...