PAGE 9 OF 69
1021 IH-9554
MENU SETTINGS CONTINUED
Zero2:
Perform
Span1:
Perform
Span2:
Perform
Linearity1:
Perform
Linearity2:
Perform
Geographic
Adjustment:
Set 0…12…31*
End Calibration:
Exit menu
*Bold always represents factory default value.
ZERO2 [
ZERO
]
Initiates a second scale zero calibration.
SPAN1 [
SPAN
]
Initiates a span calibration procedure (zero and span).
A span calibration is important when initially setting up
the scale.
SPAN2 [
SPAN2
]
Initiates a second scale span calibration procedure.
LIN1 [
LIN]
Initiates a linearity calibration procedure (zero,
mid-point and span).
LIN2 [
LIN2
]
Initiates a second scale linearity calibration procedure.
GEO [
GEO
]
Geographical Adjustment Factor (GEO) is used to adjust
the calibration based on the current location. Settings
from 0 to 31 are available with 12 being the default.
Determine the GEO factor that corresponds to your
location. (See table on page 15)
END CAL [
END
]
Advance to the next menu or return to the top of the
current menu.
SETUP MENU
Enter this menu to set scale parameters. Default settings
are in bold.
Reset
no, yes
Dual Scale
off, on
Grad2
1…9999
Power on unit
0.00005…0.5
Zero Range
auto, kg, g, lb, oz, lb:oz
Auto Opt
off, on
Auto Tare
on, off, on-acc
Beeper Opt
off, on
Beeper Signal
off, accept, under, over, under-over
Beeper Key
off, on
Accumulation
off, auto, manual
End Setup
Exit menu
RESET [
RESET
]
Reset the Setup menu to factory defaults.
• NO = not reset
• YES = reset
DUAL SCALE [
D.SCALE
]
Set the status of the second scale input (Scale 2).
• OFF = disabled
• ON = enabled
CAP2 [
CAP2
]
Set the capacity of Scale 2.
• 1…9999
GRAD2 [
GRAD2
]
Set the readability of Scale 2.
• 0.00005…0.5
POWER ON UNIT [
PWWR.UN
]
Set the unit of measure displayed at startup.
• AUTO = last unit in use when turned off
• kg = kilograms
• g = grams
• lb = pounds
• oz = ounces
• lb:oz = pound ounces
ZERO RANGE [
ZERO
]
Set the percentage of scale capacity that may
be zeroed.
• 2% = zero up to 2 percent of capacity
• 10% = zero up to 10 percent of capacity
AUTO OPT [
A.OPT
]
Set the Automatic Optimization.
• OFF = disabled
• ON = APW automatically optimized