PAGE 5 OF 18
0720 IH-8816
SPECIFICATIONS
TROUBLESHOOTING
ERROR
CODE
DESCRIPTION
CORRECTIVE ACTION
101
Received signal too weak/
measuring time too long.
Use target plate or change target surface.
102
Received signal too high.
Target too reflective. Use target plate or change target
surface.
201
Too much background light.
Reduce background light on target area.
202
Laser beam interrupted.
Remove obstacle and repeat measurement.
Range
4" to 100' (0.1 m to 30 m)
Measuring Accuracy*
± 3/32" (± 2 mm)*
Resolution**
1/16" (1 mm)**
Laser Class
2 (IEC/EN 60825-1 : 2014)
Laser Type
620-690 nm, Power
≤
1 mW
Laser/Backlight Automatic Switch Off
After 30 seconds
Auto Power Switch Off
After 90 seconds
Continuous Measuring
Yes
Area/Volume
Yes
Battery Life
Up to 3,000 measurements ( 2,500 with Bluetooth )
Dimensions (H x D x W)
4.72 x 1.91 x 1.02" (120 x 48.5 x 26 mm)
Weight (with Batteries)
3.21 oz. (100 g)
Storage Temperature Range
14 to 140ºF (-10 to 60ºC )
Operating Temperature Range
32 to 104ºF (0 to 40ºC )
* Under favorable conditions (good target surface, room temperature) up to 33 ft (10m). Under unfavorable
conditions, such as bright sunlight, a very weak reflecting target surface or large temperature fluctuations,
the error can increase by ± 0.003 in/ft. (± 0.25 mm/m) for distances over 33 ft. (10m).
** Resolution is the finest measurement you can see. In inches, that is 1/16". In millimeters, that is 1 mm.
NOTE: If "INFO" appears on the display window with a code number, perform the
corresponding corrective action.