5. 

Up (+) and Down (–) Arrow Buttons

 – These raise 

or lower desired set temperature. When changing 

set point, pressing the + or – key, the word SET will 

appear on the display and the current set point 

flashes ON and OFF. The value of the set point 

is changed 1º each time + or – is pressed. The 

adjusted set point flashes on and off 12 times after 

the last change and then returns to display room 

temperature.

NOTE: Lowering or raising the set point will 
not change the supply air's temperature. For 
best results, always adjust the set point to a 
temperature the A/C unit can cycle on and off 
at to avoid operational issues, such as freezing 

or rapid discharge fan cycling. The A/C unit is 
designed to maintain the set point when sized 

properly. Constant operation without achieving 
the set point may shorten the expected 

operational life of the system.

NOTE: The lowest set point temperature 
available for the A/C unit is 60º F, and the 
highest setting is 95º F. The control will not 
allow adjustments beyond these ranges.

SYSTEM OPERATION

1. 

Turn on the A/C system

 – Pressing the ON/OFF button 

once on control panel will put unit in ON position. 

ON will show on the right side of display as well as 

the previously chosen mode.

2. 

Cool 

– If unit was previously set to cooling mode,   

COOL will display. If compressor is running, COOL 

will flash on the display. This will likely happen if unit 

has been sitting for over two minutes, unless set point 

is lower than the current room temperature. In this 

case, unit is ready to automatically turn on once 

the temperature rises above the set point. If the unit 

was recently turned off or the unit turned itself off 

because it reached the set point, the compressor will 

not turn on until the system waits for approximately 

two minutes. This prevents the compressor from being 

damaged due to a condition called short cycling. F 

(or C) will flash when unit is in timeout condition. When 

the compressor starts, the F will stop flashing and   

COOL will begin flashing.

NOTE: Condenser fan will not start immediately 
with the compressor. If the display flashes 99, 
this indicates ambient temperature of 99º F or 
more. This is normal and will stop flashing when 
the ambient temperature falls below 99º F. 

3. 

FAN

 – If the unit was previously set to fan mode,  

FAN will display and fan will start to run.

BUILT-IN SAFEGUARDS

TIME DELAY

This protects A/C unit from potential damage by 

delaying the compressor from starting before the 

pressures in the mechanical system equalize. This 

always activates when A/C unit cycles off, is turned off, 

power is lost and then restored or the operational mode 

is changed. Display flashes F or C if the time delay is 

activated.

HIGH-PRESSURE SWITCH AND ALARM

This protects A/C unit from potential damage to the 

mechanical system by shutting down, sounding an 

alarm and displaying a fault code (AL) when the system 

pressure exceeds safe operating conditions. The high 

pressure switch is a manual reset switch located in the 

condenser inlet on the back of the system and labeled 

HP Reset; it must be reset after the switch is activated 

and the condition causing the trip is corrected.

AUTOMATIC RESTART

In the event of a power loss, A/C unit will resume 

operation when the power is restored. All operational 

functions are preserved in the memory of the 

microprocessor board, including the ON/OFF selection.

CONDENSATE TANK AND HIGH-LEVEL ALARM

All A/C units come standard with an internal condensate 

tank. Tank is equipped with an overflow safety cut-off. 

When tank is full, the safety will automatically shut down 

unit, sound an alarm and display a fault code (CF). This 

prevents accidental flooding of the conditioned space. 

To continue operation, empty water tank.

SERVICE PORTS

Service ports are located in filter access compartment 

in the front of A/C unit below control panel. These 

give service personnel a connection point for service 

gauges to monitor the operating pressures of A/C unit 

refrigeration system.

APPLICATION REQUIREMENTS

AIR TEMPERATURE

The environmental requirements of the A/C unit at the 

installation site are 60-110º F for the condenser make-up 

air located on the back of the unit. If unit is operated in 

an environment above 110º F, the high pressure switch 

may trip, stopping the unit’s compressor.

OPERATION CONTINUED

Summary of Contents for H-8771

Page 1: ...ied and re installed Turning the A C unit off will stop the alarm 1 Remove the float switch jack by pulling it straight back Remove the condensate bottle by pushing the front of the bottle slightly downward and then pull the bottle out 2 Remove the cap threaded onto the bottle by turning counterclockwise Empty collected water and return cap back onto bottle by turning clockwise Do not cross thread...

Page 2: ...into the conditioned space 4 Place unit in designated area and connect duct from ceiling kit to top of unit To fasten duct to exhaust port collar squeeze tab to open clamp of the buckle to thread strap through bottom side of buckle then pull strap as tightly as possible through buckle Confirm that duct is secured by lifting up on the duct NOTE The area where discharge air is directed must be open ...

Page 3: ...y will show the current room temperature The unit is set to OFF and the fan is set to default position A two minute time delay starts indicated by a flashing F on the display If nothing appears on the display refer to Troubleshooting on pages 5 7 CONTROL PANEL The control panel display shows the current operational status of the unit See Figure 5 1 ON OFF Button Pressing this button engages or shu...

Page 4: ...with the compressor If the display flashes 99 this indicates ambient temperature of 99º F or more This is normal and will stop flashing when the ambient temperature falls below 99º F 3 FAN If the unit was previously set to fan mode FAN will display and fan will start to run BUILT IN SAFEGUARDS TIME DELAY This protects A C unit from potential damage by delaying the compressor from starting before t...

Page 5: ...d performance and or high pressure safety trip OPERATION CONTINUED MAINTENANCE AIR FILTERS Unit comes with filters installed on the evaporator inlet to prevent dust and debris from entering system and circulating into conditioned space Filters are disposable and must be periodically checked and replaced based on the air quality of conditioned space NOTE Failure to maintain filters will cause restr...

Page 6: ...reaker and verify incoming power to connector Call Uline Customer Service at 1 800 295 5510 for assistance System trips breaker on startup Incoming power is incorrect breaker is undersized or faulty and or power cable is too long and or undersized Verify the circuit and power cable is within the system s specifications consult with a licensed electrician or call Uline Customer Service at 1 800 295...

Page 7: ...heck for blocked air flow from the supply air Replace air filters Adjust set point to allow the unit to cycle Add another A C system or larger capacity model Install service gauges to view pressures Call Uline Customer Service at 1 800 295 5510 for assistance 99 flashes on display Ambient room temperature is over 99º F Unit is working properly Lowering of room temperature will rectify the flashing...

Page 8: ...volver a instalar Apagar la unidad de aire acondicionado detendrá la alarma 1 Retire la entrada del interruptor flotante jalándola hacia atrás Retire el bote de condensado presionando la parte frontal del bote ligeramente hacia abajo y luego extraiga el bote 2 Retire la tapa roscada en el bote girando en el sentido contrario de las manecillas del reloj Vacíe el agua recolectada y vuelva a colocar ...

Page 9: ... descarga de aire caliente se regrese al espacio condicionado 4 Coloque la unidad en el área designado y conecte el conducto del kit de techo a la parte superior de la unidad Para sujetar el conducto al reborde del puerto de escape apriete la pestaña para abrir la abrazadera de la hebilla para pasar la correa por debajo de la hebilla luego jale la correa lo más apretado posible por la hebilla Conf...

Page 10: ...ntalla del aire condicionado mostrará la temperatura ambiente actual La unidad está configurada en apagado OFF y el ventilador en la posición predeterminada Inicia un tiempo de retraso de dos minutos indicado por una F parpadeando en la pantalla Si no aparece nada en la pantalla consulte la sección de Solución de Problemas en las páginas 12 14 PANEL DE CONTROL La pantalla del panel de control mues...

Page 11: ...ca la temperatura ambiente de 37º C 99º F o más Esto es normal y dejará de parpadear cuando la temperatura ambiente baje a menos de 37º C 99º F 3 FAN Ventilador Si la unidad estaba configurada en modo de ventilador previamente FAN se mostrará y el ventilador empezará a funcionar MEDIDAS DE SEGURIDAD INTEGRADAS TIEMPO DE RETARDO Esto protege a la unidad de aire acondicionado de un daño potencial re...

Page 12: ... presión CONTINUACIÓN DE FUNCIONAMIENTO MANTENIMIENTO FILTROS DE AIRE La unidad viene con filtros instalados en la entrada del evaporador para evitar la entrada de polvo y basura en el sistema y que circulen en el espacio acondicionado Los filtros son desechables y se tiene que revisar y cambiar periódicamente según la calidad del aire en el espacio acondicionado NOTA Si no se cumple con el manten...

Page 13: ...rruptor automático y verifique la energía entrante al conector Comuníquese a Servicio a Clientes de Uline al 800 295 5510 para asistencia El sistema bota el interruptor automático al iniciar La energía entrante está incorrecta el interruptor automático es de tamaño reducido o está descompuesto o el cable eléctrico está muy largo o de tamaño reducido Verifique que el circuito y cable eléctrico está...

Page 14: ...ción en la circulación de aire del suministro de aire Reemplace los filtros de aire Ajuste el punto configurado para permitir que la unidad cicle Agregue otro sistema de aire acondicionado o un modelo de capacidad más grande Instale calibradores de servicio para visualizar las presiones Comuníquese a Servicio a Clientes de Uline al 800 295 5510 para asistencia 99 parpadea en la pantalla La tempera...

Page 15: ...nuer l opération la bouteille collectrice doit être retirée vidée puis réinstallée Lorsque vous éteignez le climatiseur l alarme s éteint 1 Retirez la prise de l interrupteur à flotteur en le tirant vers l arrière Retirez la bouteille de condensats en poussant l avant de la bouteille légèrement vers le bas puis en tirant sur celle ci 2 Dévissez le bouchon dans le sens antihoraire afin de l ôter Vi...

Page 16: ...afond manquante pour éviter que l air chaud rejeté ne soit réintroduit dans l espace climatisé 4 Placez l appareil à l endroit désigné et reliez la conduite de l ensemble pour plafond sur le dessus de l appareil Pour fixer la conduite au collier de l orifice de sortie pressez la languette pour ouvrir l attache de la boucle et faites passer la sangle à travers la partie inférieure de la boucle puis...

Page 17: ...he la température ambiante L appareil est réglé sur OFF Arrêt et le ventilateur est dans sa position par défaut Une fonction de temporisation d une durée de deux minutes est activée ce qu indique un F clignotant à l écran Si rien ne s affiche à l écran consultez la section Dépannage aux pages 19 à 21 PANNEAU DE COMMANDE L écran du panneau de commande affiche l état opérationnel de l appareil Voir ...

Page 18: ...l écran ceci indique une température ambiante de 99 ºF ou plus Ceci est normal et le clignotement cesse lorsque la température ambiante chute en deçà de 99 ºF 3 FAN Ventilateur Si l appareil a été préalablement programmé en mode ventilateur FAN s affiche et le ventilateur se met en marche DISPOSITIFS DE SÉCURITÉ INTÉGRÉS TEMPORISATION Ce dispositif permet de protéger le climatiseur de dommages pot...

Page 19: ...diminution du rendement et ou un déclenchement du commutateur haute pression FONCTIONNEMENT SUITE ENTRETIEN DÉPANNAGE PROBLÈME CAUSES RECOMMANDATIONS L appareil affiche CF l alarme sonore ne s éteint pas après le démarrage ou pendant le fonctionnement de l appareil Le réservoir interne de condensats est plein ou la prise de l interrupteur à flotteur de condensats n est pas installée ou positionnée...

Page 20: ... niveau du connecteur Appelez le service à la clientèle Uline au 1 800 295 5510 pour obtenir de l aide Le système fait sauter le disjoncteur lors de la mise en marche L alimentation électrique n est pas appropriée le disjoncteur est de calibre insuffisant ou défectueux et ou le cordon d alimentation est trop long et ou de calibre insuffisant Assurez vous que le circuit et le cordon d alimentation ...

Page 21: ...res à air Réglez le point de consigne pour permettre à l appareil d alterner les cycles Ajoutez un autre système de climatisation ou un modèle de capacité supérieure Installez des jauges de service pour contrôler la pression Appelez le service à la clientèle Uline au 1 800 295 5510 pour obtenir de l aide 99 clignote à l écran La température ambiante dans la salle est supérieure à 37 ºC 99 ºF L app...

Reviews: