  H-8022, H-8023

IBC TANK HEATER

1-800-295-5510

uline.com

The controller plugs into the GFCI-protected power 

supply (wall, etc.). The controller will power up when 

power supply cord is plugged in.

The IBC tank heater plugs into the output receptacle 

cord of the controller. The controller regulates power 

to the receptacle depending upon the temperature of 

the probe/sensor versus the OFF and ON temperatures 

programmed into the controller.

NOTE: Place the temperature sensor between 
the blanket and the IBC. (See Figure 1)

CAUTION! Improper probe placement can 

result in unsatisfactory performance and/or 

damage to your vessel, product or blanket. 
(See Figure 2)

CAUTION! Do not submerge the temperature 
sensor – it is not waterproof. (See Figure 2)

Figure 1

Figure 2

OPERATION

Input Power Supply Cord

Gray temperature sensor lead with 

steel encased temperature  

sensor/probe (6' long)

Hanger Kit

Controller

Output Cord 

with Connector 

(2' long)

Para Español, vea páginas 4-6.

Pour le français, consulter les pages 7-9.

Summary of Contents for H-8022

Page 1: ...and ON temperatures programmed into the controller NOTE Place the temperature sensor between the blanket and the IBC See Figure 1 CAUTION Improper probe placement can result in unsatisfactory performa...

Page 2: ...ng on application As the contents in the vessel approach the desired temperature this difference will be much less The green light will glow when there is power to the output receptacle and go off whe...

Page 3: ...ng off the heater in the rare case of sensor failure Set this to one if user wants to run full power without temperature control if sensor malfunctions F or C Temperature Units The units can be switch...

Page 4: ...punto de ajuste de temperatura OFF y ON que se haya programado en el regulador NOTA Coloque el sensor de temperatura entre la manta y el IBC Vea Diagrama 1 PRECAUCI N Colocar la sonda de manera inadec...

Page 5: ...e a la temperatura deseada la diferencia ser menos notoria La luz verde se iluminar cuando haya corriente entrando al recept culo de salida y se apagar cuando la corriente no est conectada al recept c...

Page 6: ...el calentador en caso de que falle el sensor Aj stelo a uno si desea utilizar la m xima potencia sin control de temperatura si el sensor no funciona correctamente F o C Unidades de Temperatura La unid...

Page 7: ...ar rapport aux temp ratures ON et OFF programm es dans le r gulateur REMARQUE Placez le capteur de temp rature entre la couverture et le GRV Voir Figure 1 MISE EN GARDE Un emplacement inad quat de la...

Page 8: ...atteint la temp rature souhait e cette diff rence est moins significative La lumi re verte est allum e lorsque l alimentation est pr sente la prise de sortie et s teint lorsqu elle est coup e de la p...

Page 9: ...a pour but d teindre l l ment chauffant dans les rares cas de d faillance du capteur R glez ce param tre sur un si l utilisateur souhaite un fonctionnement pleine puissance sans contr le de temp ratur...

Reviews: