![U-Line Echelon CLRCO2175S41 Installation Manual Download Page 21](http://html1.mh-extra.com/html/u-line/echelon-clrco2175s41/echelon-clrco2175s41_installation-manual_3415860021.webp)
03/2008
21
www.U-LineService.com
CLR2160/CLRCO2175 Ice Makers
2. If the ice maker is not level, adjust the feet on the
corners of the unit as necessary (see
Figure 50
).
3. Check the levelness after each adjustment and repeat
the previous steps until the unit is level. Go on to
9 Install the Unit
.
Installation Tip
If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8" less than the opening’s rear height. Shorten
the unit height in the front by adjusting the front feet.
This allows the unit to be gently tipped into the opening.
Readjust the front feet to level the unit after it is correctly
positioned in the opening.
Installation of the CLR2160
1. Open the water supply valve in the main water source.
2. Plug in the power cord.
3. Open the door and press the POWER icon (see
Figure
53
,
1
) (
Page
23
) on the display panel until OFF is
displayed.
Note:
If the unit is NOT turned
OFF
, water will
immediately start flowing into the unit when it is first
plugged into the electrical outlet.
4. Gently push the unit into position. Be careful not to
kink the drain or water supply line or entangle the
electrical cord.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" below the
countertop.
Test the drain system by pouring one gallon of water into
the ice bin. The water should drain freely and there should
be no leakage.
Installation of the CLRCO2175
1. Open the water supply valve in the main water source.
2. Plug in the power cord.
3. Open the door and press the POWER icon (see
Figure
53
,
1
) (
Page
23
) on the display until OFF is displayed.
Note: If the unit is NOT turned
OFF
, water will
immediately start flowing into the unit when it is first
plugged into the electrical outlet.
4. Gently push the unit into position. Be careful not to
kink the drain or water supply line or entangle the
electrical cord.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" below the
countertop.
6. Test the drain system by pouring one gallon of water
into the ice bin. The water should drain freely and there
should be no leakage.
7. Remove the tape from the glass shelves and wipe out
the inside of the unit with a clean, water-dampened
cloth.
Turn Foot to Adjust
Figure 50
9 Install the Unit