2075DWRR
17
Design
■
Features
■
Performance
8
Noisy
Cause
Remedy
a. Copper refrigeration tube touching cabinet
a. Carefully adjust tubing
b. Fan blade touching shroud
b. Adjust fan mounting or shroud
c. Fan blade obstruction (wiring, foam insulation,
c. Remove obstruction
packaging material)
9
Fresh food or wine temperature too cold
Cause
Remedy
a. Controller set too cold
a. Adjust controller
b. Defective controller
b. Replace controller
c. Wiring defect
c. Check wiring
d. Thermistor not pushed all the way into the well
d. Check thermistor location
10
Excessive condensation on mullion
Cause
Remedy
Mullion heater not operating - check resistance
a. Good resistance
a. Bad heater switch
b. No resistance
b. Heater wiring
Note:
The heater will not operate in ambients over 90° F.
Summary of Contents for Echelon 2075DWRR
Page 2: ......
Page 3: ...INTRODUCTION 1 Design Features Performance General Information 2075DWRR 2075DWRWC CO2075DWR...
Page 4: ...NOTES 2 Design Features Performance...
Page 7: ...General Information...
Page 8: ...GENERAL INFORMATION Design Features Performance...
Page 13: ...2075DWRR...
Page 14: ...2075DWRR Design Features Performance...
Page 21: ...2075DWRR WIRING DIAGRAM 42184 F 2075DWRR 15 Design Features Performance...
Page 28: ...NOTES 22 Design Features Performance...
Page 29: ...2075DWRWC...
Page 30: ...2075DWRWC Design Features Performance...
Page 46: ...NOTES 2075DWRWC 38 Design Features Performance...
Page 47: ...CO2075DWR...
Page 48: ...CO2075DWR Design Features Performance...
Page 64: ...54 Design Features Performance NOTES CO2075DWR...
Page 72: ...62 Design Features Performance NOTES...
Page 73: ...INTRODUCTION 63 Design Features Performance NOTES...
Page 74: ...INTRODUCTION 64 Design Features Performance NOTES...