TROUBLESHOOTING
BEFORE CALLING FOR SERVICE
If the unit appears to be malfunctioning, read through NORMAL OPER-
ATION first. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its
remedy before calling for service. The problem could be something very
simple which can be solved without a service call.
TROUBLESHOOTING GUIDE
NEVER attempt to repair or perform maintenance on the
unit until the main electrical power has been disconnected.
Troubleshooting — What to check when problems occur
Problem
Possible Cause
Remedy
The unit does
No electrical power
Make sure power cord
not operate
to the unit
is plugged in. Check for
blown fuse or tripped
circuit breaker
Cycle selector switch
Make sure cycle selector
set improperly
switch is set to ICE
Low air temperature
Surrounding air
around unit
temperature must be at
least 50°F (10°C)
Unit runs but no No water being
Check to see that water
ice is produced
supplied to the unit
is connected and turned
on to the unit
Unit runs but
Dirty condenser coils
Clean the condenser.
produces very
See CARE AND
little ice
CLEANING
High air temperature
Surrounding air
around unit
temperature of over
90°F (32°C). Low ice
production at high
temperatures is normal
Scale and mineral
Clean unit. See CARE
buildup in unit
AND CLEANING
!
WARNING
!
28
User’s Manual