background image

U-Line Electrical / Plumbing Specfications

13

Factory-Installed Drain Pump

If your drain line will run up to a stand pipe, disposal or spigot 
assembly, or does not otherwise meet the requirements for a 
Gravity Drain, you may have ordered the CLR2160 or 
CLRCO2175 with a U-Line P60 Drain Pump. See Below for typical 
installations requiring a Drain Pump. If you need to install a P60 
Drain Pump into your unit, see Locally-Installed Drain Pump on 
Page 

14

.

Typical Installations Requiring a Drain Pump

IMPORTANT

IMPORTANT

Before installing your U-Line CLR2160 or CLRCO2175 
with Factory-Installed U-Line P60 Pump, it is extremely 
important to check and test all hose connections at the 
drain pump. There is a possibility that hose connections 
may have loosened during shipment.

To check and test hose connections:

1. Make certain the unit is not plugged into an electrical outlet.

2. Carefully push the power cord grommet through the hole in the 

back panel.

3. Remove 12 screws and back panel.

IMPORTANT

IMPORTANT

Back panel serves as a guard. DO NOT put your hands 
inside the ice maker cabinet or attempt to touch any 
components except the discharge tube during testing.

4. Check that the clamps and hose connections are tight at the 

following areas:

• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)

5. Place a suitable container beneath the pump’s discharge tube. 

(The bucket must be able to hold a minimum of one gallon.)

6. Plug the ice maker power cord into a properly grounded, 

polarized electrical outlet.

7. Place the unit into OFF mode by holding power key for 10 

seconds. Not doing this will cause the unit to start the fill cycle 
which will run for 3 minutes.

8. Verify pump operation by pouring one gallon of water into the 

ice storage bin of the ice maker. The pump should energize and 
pump the water into the container.

9. At this time, verify that all tube and clamp connections are tight 

and leak-free. 

10. Unplug unit power cord from electrical outlet.

11. Reinstall back panel.

Cold

Water

Hot

Water

Waste

Waste

Shut-Off

Valve

Stand Pipe
P60 Pump Required

Air Gap

(Optional Hook-Up)

Cold

Water

Hot

Water

Waste

Shut-Off

Valve

Disposal Assembly
P60 Pump Required

Waste

Cold

Water

Shut-Off

Valve

Hot

Water

Air Gap

(Optional Hook-Up)

Y-Branch Tailpiece
P60 Pump Required

Power

Cord

Grommet

Drain

Fitting

Back

Panel

Water

Connection

Screws

Back View

Side View

B

B

A

C

C

Summary of Contents for CLR2160

Page 1: ... The Built In Undercounter Leader Since 1962 CLEAR ICE MODELS CLEAR ICE COMBO MODELS ICE COMBO MODELS U LINE COM CO1175 CO2175 CLR2160 CLRCO2175 INSTALL GUIDE CO29 ...

Page 2: ...nment and Adjustment 6 Door Reversability 6 Reversing the door 6 Self Closing Doors Door Alignment and Adjustment 8 Door Reversability 8 Reversing the door 8 Door Panel Installation Custom 1 4 Thick Door Panel Insert 10 Door Panel Preparation 10 Panel Dimensions 10 Door Panel Installation 10 Prepare Power Supply Electrical Specifications 11 Receptacle Location 11 Prepare Plumbing Water Supply Conn...

Page 3: ...ical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adaptor Altering cutting of power cord removal of power cord removal of power plug or direct wiring can cause serious injury fire and or loss of property and or life and will void the ...

Page 4: ... Panel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer Order U Line Part No WATERHOOKUP Exterior Cleaning Black and White Models Black and White surfaces may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe ...

Page 5: ...llations CLR2160 Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations 8 24 Minimum 24 1 4 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 15 1 4 8 24 CO29 Series Follow the cut out drawing The 21 1 16 width allows 1 ...

Page 6: ...3 16 34 3 16 15 15 Black and White Stainless Steel 23 1 4 3 7 8 23 1 4 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 5 16 34 3 16 24 Add 3 16 to Depth For Water Line Clearance 3 13 16 34 3 16 24 STAINLESS CO1175 23 1 16 Add 3 16 to Depth For Water Line Clearance 3 13 16 CO2175 Series 34 3 16 24 Black andWhite Stainless Ste...

Page 7: ...ements The units are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers If the ambient temperature is expected to drop below 45 F 7 C drain all water from the unit to prevent freezing damage which is not covered by the...

Page 8: ...th black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hinged Reversing the door The Hinge hardware will be removed and reinstalled on the opposite side of the cabinet The hinge plate is flipped over when it is reinstalled on the opposite side of the cabin...

Page 9: ...sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator assembly was removed 9 Install screws into holes on opposite side where the hinge was removed Replace nuts if used 1 1 2 3 4 Prepare door for reinstallation For black or white doors 1 Remove plastic h...

Page 10: ... sets 3 Turn the door upside down and inspect the hinge plate mounting holes The plate has slotted mounting holes Loosen but do not remove the two hinge plate screws 1 4 If door edge opposite the hinges needs to move up move plate toward outside of door 2 If door edge needs to move down move plate toward inside of door 3 Repeat until top edge of door is parallel with top of cabinet and tighten scr...

Page 11: ...er inserts as shown on the new bottom hinge 4 Remove existing bottom hinge Remove the existing bottom hinge three screws 2 Reinstall hinge to top opposite Install the hinge just removed from the bottom to the TOP opposite side of the cabinet three screws 2 Reinstall Hole Plugs Install plastic screw plugs three each top and bottom 3 into holes where hinge hardware was removed Prepare door for reins...

Page 12: ... tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force Model Width Height CLRCO2175 23 1 32 27 11 16 CLR2160 14 1 32 27 11 16 CO1175 22 15 16 26 15 16 CO29 19 13 16 21 13 32 CO2175 23 1 32 27 11 16 3 Remove the two outside screws holding door handle Slightly separa...

Page 13: ...been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping H...

Page 14: ...en using the two wrenches Drain Connection CLR2160 CLRCO2175 IMPORTANT IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not allow the unit to drain below itself We strongly recommend the use of a U Line drain kit for both gravity pump installations A complete drain kit containing all the items needed to connect your unit are available from your dealer Part No ...

Page 15: ...er cabinet or attempt to touch any components except the discharge tube during testing 4 Check that the clamps and hose connections are tight at the following areas Discharge tube A Drain tube B Vent tube C 5 Place a suitable container beneath the pump s discharge tube The bucket must be able to hold a minimum of one gallon 6 Plug the ice maker power cord into a properly grounded polarized electri...

Page 16: ...e event of a pump failure It must have an operating temperature range of 50 F to 110 F 10 C to 40 C IMPORTANT IMPORTANT In the event of a power outage restricted drain or pump failure the failure to use the U Line P60 drain pump or a pump with the above listed specifications could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages ...

Page 17: ...rst plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the unit into position Be careful not to kink the water supply line or entangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top...

Page 18: ...lution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly Also re check leveling from front to back of the unit and readjust if necessary Make sure that pivot plate is installed correctly Problem Q The custom overlay door was designed to align with the rest ...

Page 19: ... today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class products that build on the company s numerous pat ents and world firsts to guide the undercounter industry in realizing its unlimited potential U LINE COM GENERAL INQUIRIES U Line Corporation P O Box 245040...

Reviews: