PARTS COUNTING CONTINUED
ESTABLISH AN AVERAGE PIECE WEIGHT (APW)
CONTINUED
6. To change the sample
size, press and hold the
No button to increment
the sample size through
the range of 1 to 100. Release the button when the
desired sample size appears on the secondary display.
7. Place the specified
number of parts on
the pan. Press the Function
button to accept. The
primary display will now indicate the number of
parts. The weight is shown on the secondary display.
8. Pressing the Function
button momentarily
displays the APW on the
secondary display. The
example shows an APW of 2.000g.
CLEARING THE APW
Press and hold the Mode button until COUNT is shown
on the secondary display.
PERCENT WEIGHING
Use the Percent Weighing
Mode to measure the weight
of a sample as a percentage
of a preestablished reference
weight.
1. Press and hold the Mode button. When PERCENT
displays, release the button. The primary display
shows PERCENT. If a Reference Weight is stored in
memory, the secondary display shows CLEAR REF?
(blinking). Press No to use the stored reference
weight and begin Percent Weighing.
2. Press Yes to clear the saved Reference Weight.
ESTABLISHING A REFERENCE WEIGHT
If no Reference Weight is stored, a Reference Weight
must be established. The secondary display shows
PUT SAMPLE. The current weight is shown on the
primary display.
1. Place the sample on the
pan and press the Function
button. This example
illustrates 50 grams as the
reference weight.
2. Remove the reference
weight and place the
item to be compared on
the pan. The balance
indicates the actual percentage on the primary
display. The secondary display indicates the weight
in the selected measuring unit.
3. Pressing the Function button momentarily displays
the reference weight on the secondary display.
CLEARING THE REFERENCE WEIGHT
Press and hold the Mode button until PERCENT is shown
on the secondary display.
DISPLAY HOLD
The Display Hold Mode allows the user to capture and
store the highest (stable) weight in a series of weight
measurements. The Display Hold Mode provides the
user with three (3) operating modes: Automatic,
Semi-automatic and Manual.
AUTOMATIC MODE :
• Highest stable weight captured automatically.
• Ready for next measurement automatically when
pan is cleared.
SEMI-AUTOMATIC MODE :
Highest stable weight captured automatically. Ready for
next measurement after pressing FUNCTION key.
MANUAL MODE :
Press Function button to take measurement. Ready for
next measurement after pressing Function button.
CLEAR PEAK :
Press and hold Function button - release when
Mode>DISP/HOLD appears. In all modes, the actual
weight is shown on the primary display when READY
or CLEAR PAN is shown on the secondary display. The
current Peak value is shown on the primary display
when HOLD is shown on the secondary display. Display
icons show weighing unit, stability and center of zero
when actual weight is displayed. The weighing unit only
is shown when the Peak weight is displayed.
OPERATION CONTINUED