Troubleshooting

BEFORE CALLING FOR SERVICE

If you think your U-Line product is malfunctioning, read 
the CONTROL OPERATION section to clearly understand 
the function of the control.

If the problem persists, read the NORMAL OPERATING 
SOUNDS and TROUBLESHOOTING GUIDE sections below 
to help you quickly identify common problems and 
possible causes and remedies. Most often, this will resolve 
the problem without the need to call for service. 

IF SERVICE IS REQUIRED

If you do not understand a troubleshooting remedy, or 
your product needs service, contact U-Line Corporation 
directly at +1.800.779.2547.

When you call, you will need your product Model and 
Serial Numbers. This information appears on the Model 
and Serial number plate located on the upper right or rear 
wall of the interior of your product. 

NORMAL OPERATING SOUNDS

All models incorporate rigid foam insulated cabinets to 
provide high thermal efficiency and maximum sound 
reduction for its internal working components. Despite this 
technology, your model may make sounds that are 
unfamiliar. 

Normal operating sounds may be more noticeable because 
of the unit’s environment. Hard surfaces such as cabinets, 
wood, vinyl or tiled floors and paneled walls have a 
tendency to reflect normal appliance operating noises.

Listed below are common refrigeration components with a 
brief description of the normal operating sounds they 
make. NOTE: Your product may not contain all the 
components listed.

• Compressor: The compressor makes a hum or pulsing 

sound that may be heard when it operates. 

• Evaporator: Refrigerant flowing through an evaporator 

may sound like boiling liquid. 

• Condenser Fan: Air moving through a condenser may 

be heard.

• Automatic Defrost Drain Pan: Water may be heard 

dripping or running into the drain pan when the unit is 
in the defrost cycle.

TROUBLESHOOTING GUIDE

DANGER

!

ELECTROCUTION HAZARD. Never attempt to 
repair or perform maintenance on the unit 
before disconnecting the main electrical power.

Troubleshooting - What to check when problems occur:

Problem

Possible Cause and Remedy

Digital Display 

and Light Do Not 

Work.

Ensure power is connected to the unit.
If the unit is cooling, it may be in Sabbath 

mode.

Interior Light 

Does Not 

Illuminate.

The light bulb may be defective.
If the unit is cooling, it may be in Sabbath 

mode. 

Light Remains on 

When Door Is 

Closed.

For glass door models, press the light icon 

and close the door.
Check reed switch.

Unit Develops 

Frost on Internal 

Surfaces.

Frost on the rear wall is normal and will melt 

during each off cycle. 
If there is excessive build-up of 1/4" or 

more, manually defrost the unit. 
Ensure the door is closing and sealing 

properly. 
High ambient temperature and excessive 

humidity can also produce frost. 

Unit Develops 

Condensation on 

External 

Surfaces.

The unit is exposed to excessive humidity. 

Moisture will dissipate as humidity levels 

decrease.

Digital Display 

Functions, But 

Unit Does Not 

Cool.

Ensure the unit is not in “Showroom Mode.”
Momentarily unplug or interrupt power 

supply to the unit.

Digital Display 

Shows ER or E 

Followed by a 

Number.

E3 indicates the door may be opened too 

long. Ensure the door is closing properly. 

For other error codes contact U-Line 

Customer Service.

Summary of Contents for 1224DWR

Page 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series 1224DWR 24 Solid Door Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...ectrical Cutout Dimensions Product Dimensions Anti Tip Bracket General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Plinth Installation Drawers Free Standing Kit Opera...

Page 3: ...ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all ava...

Page 4: ...jury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...

Page 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Page 6: ...C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity a...

Page 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Page 8: ...he rear CAUTION Unit can NOT be installed behind a closed cabinet door Never remove the round grounding prong from the plug and never use a two prong grounding adapter Never use an extension cord to c...

Page 9: ...mensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 23 1 4 591 mm Includes 3 4 20 mm Integrated Panel 34 1 8 to 35 1 8 867 mm to 892 mm...

Page 10: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...

Page 11: ...ust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently...

Page 12: ...s installed When applying an integrated panel to a unit ensure that both sides are finished in order to prevent warping In some overlay panel frame installations the panel may be visible through the g...

Page 13: ...use of bar clamps to secure the panel to the door drawer If using tape be certain the tape will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood pa...

Page 14: ...move clamps from door drawer NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 12 Starting at...

Page 15: ...nect electric power to the unit before removing the grille WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the...

Page 16: ...ADJUSTING DRAWER ALIGNMENT WARNING SHOCK HAZARD The unit must be unplugged from the wall outlet during drawer removal adjustment and re installation DRAWER REMOVAL 1 Confirm that the unit is unplugge...

Page 17: ...other slide Measure to confirm 3 Mark new drilling holes using different sets of mounting holes on the slide Note Front location holes are shown Corresponding rear holes will also need to be marked 4...

Page 18: ...stment Note The mounting holes on the slide are slightly larger than the screws diameter 1 Loosen one slide s mounting screws 2 Push the slide upward or downward to match the position of the other sli...

Page 19: ...S MAINTENANCE SERVICE RE INSTALLATION OF DRAWER CAUTION Use care when handling the drawer Drawer edges drawer rail and the unit s slide may be sharp 1 Set the drawer s rails onto the slides 2 Re insta...

Page 20: ...ly used when unit is not installed in surrounding cabinetry To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligni...

Page 21: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the f...

Page 22: ...turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and beverage centers only Adjust refrigerator set point Press and release When the F or C in the...

Page 23: ...ntain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will...

Page 24: ...o perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporat...

Page 25: ...ainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always...

Page 26: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...

Page 27: ...necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the con...

Page 28: ...ent from the unit 2 Disconnect the power cord from its outlet and leave it disconnected until the unit is returned to service 3 If ice is on the evaporator allow ice to thaw naturally CAUTION DO NOT u...

Page 29: ...USER GUIDE Accessories 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Accessories 80 33027 01 Accessories Slide and Divide Bin Organizer 24 US 109 00...

Page 30: ...s listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air...

Page 31: ...r openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be ena...

Page 32: ...ervice com 3 The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration...

Page 33: ...IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Li...

Reviews: