Prepare Site

3

4 Prepare Site

Your U-Line product has been designed for either free-standing or 
built-in installation. When built-in, your unit does not require 
additional air space for top, sides or rear. However, the front grille 
must NOT be obstructed and clearance is required for an 
electrical connection in the rear.

WARNING

Unit can NOT be installed behind a closed cabinet door.

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Never remove the round grounding prong from the 

plug and never use a two-prong grounding adapter.

• Never use an extension cord to connect power to the 

unit.

IMPORTANT

IMPORTANT

Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A 
power supply (normal household current). An individual, properly 
grounded branch circuit or circuit breaker is recommended. GFCI 
(ground fault circuit interrupter) is usually not required for fixed 
location appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be sure to 
consult your local codes.

Cut-Out Dimensions

1175, 1075 & 75F Series

Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 

1115 Series

Follow the cut-out drawing The 15-3/16" width allows 1/4" for 
ease in installation and removal of the unit. 24" is the cabinet depth 
in most installations. 

29 Series

Follow the cut-out drawing. The 21-1/16" width allows 1/4" for 
ease in installation and removal of the unit. 24" is the counter 
depth in most installations. The unit is 23" deep including the door. 

ADA24 Series

Follow the cut-out drawing The 24 1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 

24”

1-1/2"

15-1/4"

7"

34-1/8"

to

35"

24"

Minimum

21-1/16"

Typical

Counter

Height

34-1/4"

to

35-1/8"

Cut-Out

Height

28-5/8"

to

28-7/8"

Filler Panel (Not Provided by U-Line) –

May Be Added Above or Below Unit

to Enclose for a Built-In Look 

7"

1-1/2"

4"

7"

24"

24-1/4"

34-1/4"

to

35-1/8"

4"

7"

24"

24-1/4"

32”

Summary of Contents for 1000 SERIES

Page 1: ...The Built In Undercounter Leader Since 1962 1000 ADA 29 Series Models U LINE COM 1175R 1115R 1175WC 1175BEV INSTALL GUIDE 29R 1075WC 1115WC 1075BEV ADA24R ADA24RG 75F...

Page 2: ...ns Other Site Requirements 6 Side By Side Installation 6 Power Supply 6 Environmental Requirements 6 Standard Doors Door Alignment and Adjustment 7 Door Reversability 7 Reversing the door 7 Wood Trim...

Page 3: ...Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong...

Page 4: ...ck and White surfaces may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe with a soft clean tow...

Page 5: ...uit interrupter is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping However be sure to consult your local code...

Page 6: ...22 7 8 3 5 8 Not Including Handle 24 1175 Refrigerator 75FB 1175 Stainless Refrigerator 1175 Stainless Wine Captain Beverage Center 34 1 8 3 9 16 34 1 8 3 9 16 34 1 8 23 1 16 3 9 16 23 5 16 23 5 16 N...

Page 7: ...ss Refrigerator ADA24RGLB 23 1 2 32 24 Refrigerator ADA24RB 23 1 4 32 24 Stainless Refrigerator ADA24RS 23 1 16 32 24 Not Including Handle 23 1 4 32 24 Not Including Handle Stainless Glass Refrigerato...

Page 8: ...lectrical Specifications Requirements Power Supply The unit requires a grounded and polarized 115 VAC 60 Hz 15A circuit normal household current Environmental Requirements The units are designed to op...

Page 9: ...h black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hi...

Page 10: ...ure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator a...

Page 11: ...and will not dissipate over time 1 Remove all screws securing wood trim to interior parts and remove the trim from the cabinet interior 2 Lightly sand and clean wood 3 Apply Minwax Water Based Wood St...

Page 12: ...e door by tilting forward and lifting off bottom hinge pin Model Width Height ADA24RB 22 15 16 26 15 16 1175R B W 22 15 16 26 15 16 1115R B W 13 15 16 26 15 16 29R B W 19 13 16 21 13 32 2 Pull door ga...

Page 13: ...e must be installed in such a manner that the grille assembly can still be removed from the unit Screw Mount Recommended 1 Remove the grille from your unit by removing the two mounting screws See belo...

Page 14: ...Line Grill Overlay Installation 12 1 8 1 4 8 1 2 3 3 32 19 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 7 16 5 16 10 5 16 11 64 2 1 8 1 2 22 7 8 23 7 8 FULL R Hole A Hole A Grille Overlay Dimensions Grille Drawing...

Page 15: ...e unit with a clean water dampened cloth Relocating the Shelves Both the glass shelves in the refrigerator and the inner door shelves can be moved to accommodate your bottles cans and containers Glass...

Page 16: ...today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class product...

Reviews: