4)
Place the lid on a flat surface and remove the
cover;
5)
Ensure that the waterplate holes and all tubes
are free of sediment. If necessary, remove the se-
diment inside the tubes with running water;
6)
Remove BioStack and store it near the device. Gently
wipe the surface of the BioStack cylinder with a soft
sponge. A coating on the cylinder surfaces is a sign that
the biological filter is active, and should not be removed
or scraped off. Please note that all AIRcel70 bioreactors
are factory tested, so it is perfectly normal to find traces
of coating on a new BioStack;
7)
Empty the tank and remove any sediment. Dispose
of the water according to applicable regulations;
8)
Replace the BioStack filter in the tank;
9)
With a soft brush, or rather with a vacuum cleaner,
vacuum the inside of the lid to clean the fan;
10)
Place the lid on the side of the tank and reconnect
the cable, screwing the connector;
11)
Insert the cover in its seat aligning it with the AIRcel70
logo, connect the cable to the power supply and turn on
the machine.
13. Correct use
13.1. General
1)
Remove all shipping brackets before installing
AIRcel70.
2)
Ensure that no solid foreign objects (e.g., nails,
needles, paper clips) or fluids are in contact with the
fan top or openings. Foreign objects can damage
device components.
3)
If U-Ox gets in your eyes, flush with plenty of warm
water. Drink plenty of water if accidentally swallowed
and consult a physician. The product is not an irritant;
if it comes in contact with the skin, wash with soap
and water.