LEXI-R422 - System integration manual
UBX-23007449 - R02
System description
Page 23 of 108
C1-Public
1.6.2
Module power-off
The graceful power-off procedure, with storage of
current parameter settings in module’s non
-volatile
memory and performing a clean network detach, can be triggered by:
•
AT+CPWROFF command (see AT commands manual
•
Low pulse on the
PWR_CTRL
pin for a valid time period (for detailed characteristics, see LEXI-R422
☞
The graceful shutdown must be started as indicated above, and then a proper
VCC
supply must
be held at least until the end of the modules’ internal switch
-off sequence, which occurs when the
generic digital interfaces supply output (
V_INT
) is switched off by the module.
A faster emergency power-off procedure of LEXI-R422, with storage of current parameter settings in
the non-volatile memory of the module, but without proper network detach, can be triggered by:
•
AT+CFUN=10 command (see AT commands manual
•
Forcing a rising edge at the GPIO input pin configured with the faster power-off function (see
section
, faster power-off)
The fastest memory-safe emergency power-off procedure of LEXI-R422, inhibiting further operations
in the
module’s
non-volatile flash memory, without executing the storage of the current parameter
settings, and without executing a clean network detach, can be triggered by:
•
AT+CFUN=11 command (see AT commands manual
•
Forcing a rising edge at the GPIO input pin configured with the memory-safe power-off function
(see section
, memory-safe power-off)
☞
The graceful shutdown procedure must be preferred to any emergency power-off procedures,
which shall be used for emergency only.
An abrupt under-voltage shutdown occurs on LEXI-R422 when the
VCC
voltage supply is removed,
dropping below the under-voltage shutdown threshold. If this occurs, it is not possible to perform the
storing of the
current parameter settings in the module’s non
-volatile memory or to perform the clean
network detach.
☞
It is highly recommended to avoid an abrupt removal of the
VCC
supply during LEXI-R422 modules
normal operations.
☞
If an abrupt power removal is unavoidable, it is recommended to apply a rising edge to the GPIO pin
configured with the memory-safe power-off function as soon as the power failure in the supply
source is detected, placing a low-ESR 470 mF capacitor at the
VCC
supply input to let the module
complete the memory-safe emergency power-off.
⚠
An abrupt removal of the
VCC
supply during LEXI-R422 modules normal operations may lead to
an unrecoverable faulty state!
LEXI-R422 modules automatically switch off, with storage of the current parameter settings in the
module’s internal non
-volatile memory and a clean network detach, after having sent the last gasp,
once the feature is enabled and triggered (see the AT commands manual
, +ULGASP AT command).