1.4

 

Connectors 

Function 

Description 

Name 

Board 

9 - 18 V Power Input 

Connector for the AC / DC power adapter of the EVK 
AC: 100-240 V, 0.8 A, 50-60 Hz / DC: +12 V, 2.5 A 

 

IEC 60417-5172 
Class II equipment 

J400 

EVB 

Cellular antenna 

SMA connector for the cellular module antenna  

J101 

ADP-U2xx 

SIM card holder 

SIM card holder 

J300 

EVB 

Cellular native USB 

Mini USB connector for cellular module native USB interface 

J313 

ADP-U2xx 

Cellular USB (UART) 

Mini USB connector for cellular module UART interface converted as USB interface 

J501 

EVB 

Cellular RS232 (UART) 

DB9 connector for cellular module UART interface converted as RS232 interface 

J500 

EVB 

Cellular headset 

Audio headset jack connector for cellular module audio interface 

J303 

EVB 

DIL B2B headers 

Dual-In-Line Board-to-Board connectors for cellular module interfaces 

J100, J103 

ADP-U2xx 

GNSS antenna 

SMA connector for the GNSS module antenna (GNSS Antenna) 

J103 

ADP-GNSS 

GNSS USB 

Mini USB connector for GNSS module USB interface 

J102 

ADP-GNSS 

GNSS backup battery 

Backup battery socket for the GNSS module (under GNSS adapter board) 

BT200 

EVB 

GND 

Ground terminals for probe reference 

J402/3/5/6 

EVB 

Table 2: EVK-U2x connector description 

 

Caution! In the unlikely event of a failure in the internal protection circuitry there is a risk of an 
explosion  when  charging  fully  or  partially  discharged  battery.  Replace  battery  when  it  no 
longer has sufficient charge for unit operation. Control the battery before use if the device has 
not been used for an extended period of time. 

 

Caution!  Risk  of  explosion  if  battery  is  replaced  with  an  incorrect  type.  Dispose  of  used 
batteries according to the instructions! 

1.5

 

LEDs 

Function 

Description 

LED # 

Board 

Color 

Main Power 

Power supply plugged in the 

9 - 18 V Power Input

 

DL401 

EVB 

 

Cellular VCC supply 

Cellular module supplied. 

Main Power Switch

 must be switched on 

DL400 

EVB 

 

Cellular native USB 

USB cable plugged in 

Cellular native USB

 connector 

DS300 

ADP-U2xx 

 

Cellular USB  

USB cable plugged in 

Cellular USB 

connector for UART access 

DL501 

EVB 

 

Cellular USB / UART 

Green light is activated when UART is routed to 

Cellular USB 

connector 

Red light blinks at UART TX or RX data on 

Cellular USB

 connector 

DL403 

EVB 

 

 

Cellular RS232 / UART 

Green light is activated when UART is routed to 

Cellular RS232 

connector 

Red light blinks at UART TX or RX data on 

Cellular RS232

 connector 

DL405 

EVB 

 

 

Cellular UART detach 

UART signals are available only on the DIL B2B connector on ADP board 

DL404 

EVB 

 

Cellular RI indicator 

RI line turns ON (active low) 

DS501 

EVB 

 

Cellular CTS indicator 

CTS line turns ON (active low) 

DS500 

EVB 

 

Cellular GPIO1 indicator 

Green light is activated when cellular GPIO1 is high 

DS107 

EVB 

 

Cellular GPIO2 indicator 

Green light is activated when cellular GPIO2 is high 

DS105 

EVB 

 

Cellular GPIO3 indicator 

Green light is activated when cellular GPIO3 is high 

DS109 

EVB 

 

Cellular GPIO4 indicator 

Green light is activated when cellular GPIO4 is high 

DS103 

EVB 

 

GNSS VCC supply 

GNSS module supply is turned ON 

DS118 

ADP-GNSS 

 

GNSS USB  

USB cable plugged in 

GNSS USB

 connector 

DS124 

ADP-GNSS 

 

GNSS timepulse 

Pulses at 1 Hz when valid GNSS fix 

DS121 

ADP-GNSS 

 

Cellular / GNSS DDC 

Cellular / GNSS module communication over DDC (I

2

C) interface 

DS132 

ADP-GNSS 

 

Table 3: EVK-U2x LEDs description 

 

Summary of Contents for EVK-U26

Page 1: ...TS EGPRS GSM Cellular evaluation kit User Guide Abstract This guide explains how to set up the EVK U26 and EVK U27 Evaluation Kits to begin evaluating the u blox SARA U2 series HSPA UMTS EGPRS GSM cellular modules www u blox com UBX 14001743 R03 ...

Page 2: ...x reserves all rights to this document and the information contained herein Products names logos and designs described herein may in whole or in part be subject to intellectual property rights Reproduction use modification or disclosure to third parties of this document or any part thereof without the express permission of u blox is strictly prohibited The information contained herein is provided ...

Page 3: ...K U2x 10 Appendix 11 A Setting up AT terminal applications for communication with EVK U2x 11 B Setting up cellular packet data connection on PC 12 B 1 How to install and configure a low data rate modem connection 12 B 2 How to install and configure a high data rate modem connection 15 C Examples of AT commands 17 C 1 Voice call 17 C 2 Data call CSD mode 17 C 3 SMS management 18 C 4 Internet connec...

Page 4: ...o evaluate other SARA U2 series modules as SARA U280 See the SARA U2 series Data Sheet 2 and SARA G3 SARA U2 series System Integration Manual 3 for the features supported by u blox SARA U2 series HSPA UMTS EGPRS GSM cellular modules SIM card holder J300 Cellular reset SW303 Cellular power on SW302 GND 9 18 V Power input J400 Cellular adapter board DL400 Main power switch SW400 DL401 Cellular anten...

Page 5: ...ing female connectors provided on top of the lower board The USB interface of the cellular module is available on the native USB connector on the cellular adapter board while the other peripherals are available on the Dual In Line male Board to Board connectors provided on the top layer of the cellular Adapter Board J100 J103 which are pin to pin compatible to the connectors on the bottom layer of...

Page 6: ...sed for an extended period of time Caution Risk of explosion if battery is replaced with an incorrect type Dispose of used batteries according to the instructions 1 5 LEDs Function Description LED Board Color Main Power Power supply plugged in the 9 18 V Power Input DL401 EVB Cellular VCC supply Cellular module supplied Main Power Switch must be switched on DL400 EVB Cellular native USB USB cable ...

Page 7: ...RSVD Not available Not available VUSB_DET 17 48 RSVD Not available J100 Pin 26 RESET_N 18 47 RSVD Not available J103 Pin 24 CODEC_CLK 19 46 RSVD Not available J103 Pins 7 8 9 10 GND 20 45 RSVD Not available J103 Pins 7 8 9 10 GND 21 44 RSVD Not available J103 Pins 7 8 9 10 GND 22 43 GND J103 Pins 7 8 9 10 J103 Pin 31 GPIO2 23 42 SIM_DET J103 Pin 23 J103 Pin 32 GPIO3 24 41 VSIM J100 Pin 13 J103 Pin...

Page 8: ...connector two COM ports are enabled in Windows the numbering of the COM ports can be seen via the Windows Device Manager The serial port for AT commands is available over the first numbered COM port opened by the driver Type of connections SW401 SW403 LED Access to cellular UART over the Cellular USB UART mini USB connector J501 ON BOARD MINIUSB DL403 Access to cellular UART over the Cellular RS23...

Page 9: ...connector J303 on EVB if the audio functionality is required 1 9 Enabling verbose error result codes Command sent by DTE user DCE response module Description AT CMEE 2 OK Enables the cellular module to report verbose error result codes 1 10 PIN code insertion when required Command sent by DTE user DCE response module Description AT CPIN 8180 OK Enter the PIN code if needed enter the PIN of the SIM...

Page 10: ...abled at any subsequent re boot of the module with the execution of the following actions Set module CODEC_CLK pin to provide 13 MHz master clock to the external Maxim MAX9860 audio codec mounted on EVK U2x Open the DDC logical channel connected to the external codec Send via DDC the specified byte sequence for codec configuration Close the DDC logical channel connected to the external codec Note ...

Page 11: ... appears 3 On the Home page set up the AT COM port for the setting values see section 1 8 Check with Windows Device Manager to find out which COM port is being used by EVK U2x Figure 3 m center Home page 4 Enable the connection to u blox cellular module by clicking on the Connect button 5 Retrieve the module and network information by clicking on the Get Info button 6 The module information is ret...

Page 12: ...a rate modem over the native USB interface of the cellular module connected to the Windows PC by the Cellular Native USB connector J313 on ADP B 1 How to install and configure a low data rate modem connection This example describes how to install and configure a low data rate packet data connection on a PC with Windows 7 operating system This uses the TCP IP stack of the PC over the UART interface...

Page 13: ...em 33600 bps Modem Properties 7 Select Change Settings Advanced 8 Add APN settings command APN shown is just an example Make sure to have the correct APN defined by the network operator 9 Click on Change Default Preferences 10 Click on OK twice and the new connection is now ready to be configured 11 To configure a new connection select Control Panel Network and Sharing Center Set up a new connecti...

Page 14: ... parameters for dial up connection The module telephone number 99 1 The specific GPRS account information for the network operator A name for the new connection e g u blox GPRS Connection 14 The packet data connection is now ready to be used with the EVK U2x To check the connection start a browser Consult the cellular network operator for username and password In most cases these can be left empty...

Page 15: ...perating system using the TCP IP stack of the PC over the native USB interface of the cellular module connected to the Windows PC by the Cellular Native USB connector J313 on ADP 1 Follow the board setup instructions in section 1 8 to provide the required connections with EVK U2x 2 Select Control Panel Network and Internet Network and Sharing Center Setup a new connection or network This opens the...

Page 16: ...1 4 Select u blox Modem USB1 AT and Data X X 7 in the picture 5 Enter the modem telephone number 99 1 select Allow other people to use this connection and click Connect to finalize the procedure Consult the cellular network operator for username and password In most cases these can be left empty ...

Page 17: ...t Hang up Outgoing voice call Command sent by DTE user DCE response module Description AT CLIP 1 OK Activation of caller line ID presentation ATD 3930012345678 OK Outgoing voice call 3930012345678 is written here as example The voice call is accepted from the network ATH OK Hang up C 2 Data call CSD mode Command sent by DTE user DCE response module Description AT CBST 7 0 1 OK Configure the data c...

Page 18: ...d to GPRS service 1 attached 0 detached AT CGDCONT 1 IP uni tim it OK Define the PDP context parameters AT CGDCONT CGDCONT 1 IP my apn 0 0 0 0 0 0 OK ATD 99 1 CONNECT Initiate the GPRS connection NO CARRIER Disconnect with sequence C 5 Internet connection in GPRS mode using internal TCP IP stack Command sent by DTE user DCE response module Description AT UPSD 0 1 my apn OK Configure PDP context pa...

Page 19: ... Description AT UGGLL 1 OK Enable the GLL message AT UGGLL UGGLL state GLL msg OK Or UGGLL state Not Available OK Read the message The last available GLL message is displayed C 8 GNSS AssistNow GNSS AssistNow Online Command sent by DTE user DCE response module Description AT UGAOP agps u blox com 46434 1000 0 OK Insert server data the parameters are written as an example AT UPSD 0 1 web omnitel it...

Page 20: ...s EVK U2x is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Related documents 1 u blox AT Commands Manual Docu No UBX 13002752 2 u blox SARA U2 series Data Sheet Docu No UBX 13005287 3 u blox SARA G3 SARA U2 series System Integration Manual Docu No UBX 13000995 4 u blox m center User Guide Docu No UBX 13001925 5 u blox EVK U2x Quick Start Docu No...

Page 21: ...ne 65 6734 3811 E mail info_ap u blox com Support support_ap u blox com Regional Office Australia Phone 61 2 8448 2016 E mail info_anz u blox com Support support_ap u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Shenzhen Phone 86 755 8627 1083 E mail info_cn u blox com Support support_cn u blox com Regio...

Reviews: