11 

 

number input box and enter the other party's number) . Press PTT to initiate private call. The interface displays: the 
first line displays the call type: private call, the second line displays the contact alias, and the third line displays the 
private call number. 
Note: If programming software is configured with the 

private call confirmed

  function of the current channel, the 

PTT will first handshake with the other party after the PTT is pressed. After the handshake is successful, the call can 
be initiated normally. 
Receive: The LED indicator lights up in green. In the display area: the first line displays 

private call

, the middle 

displays 

private  call

,  and  the  bottom  line  displays  the  caller  ID  and  the  incoming  call  icon 

.  Hold  the 

walkie-talkie in a vertical position and keep it at a distance of 1 to 2 inches (2.5 to 5.0 cm) from the mouth. If the 

channel Freq indication tone

  function is enabled, when the transmitter releases the [PTT] button, the receiver 

will hear a short tone indicating that the channel is idle and waiting for a reply. Press the [PTT] button to reply to the 
call and the LED indicator lights up in red. Release the [PTT] button to answer. 

4. Emergency alarm 

An emergency alert is used to indicate an emergency, and you can make an emergency call at any time or on any 
screen, even if there is activity on the current channel. Only digital alarms are supported. 
 
Digital alarm ((The side button is set to Emergency on/off and the alarm type is set to regular) 
Initiator: Press sidekey set as emergency on to enter the alarm mode (interface display: the first line displays Alert, 
the second line displays the alarm group call contact alias, the third line displays the group call number), local alarm 
And  wirelessly  send  alarm  commands,  alarm  mode  (emergency  alarm  or  emergency  alarm  W/call  or  emergency 
alarm w voice to follow) can be set. Press set as emergency off or the maximum number of attempts to send an 
alarm to exit the alarm mode. 
Remark:  Only  programming  software  is  equipped  with  the 

emergency  system

  of  the  current  channel,  and 

contact  of  the  reply  channel(revert  channel)  of  the  emergency system  is  a  group  call,  then the  alarm  system  can 
function. 
Receiver: After receiving the alarm command, the alarm message is displayed (interface display: the first line shows 
Recv Alert, the second line displays group call, the third line displays the alarm party alias or ID number) and sounds 
local alarm tone, press the PTT button drop out. 

5. Data commands 

5.1 Message 

Initiate: In the digital mode, press OK to enter the menu, select message, select the corresponding item, press OK to 
select Send and confirm, select contact or manual dial, press OK to send short message, and display

message send 

success

  after successful transmission and return. display "message send fail" when failed and return. 

Receive: After receiving the SMS, send a prompt tone and stop the display interface. Press OK to view, press BACK to 
exit. If there is no view, the icon 

will be displayed in the icon bar. Only all the messages will be viewed and the 

icon 

will be cleared. 

5.2 Call Alert 

Initiate: In the digital mode, select private call contact (press OK to enter menu, select private call contact or main 
interface press # key to enter private call number), select 

call alert

, press OK button to start, display 

call alert 

success

when success, displays "call alert fail" when failed. 

Receive: After receiving the call alert command, ring (the caller's contact of menu contact list has the tone function 
enabled) and pause the display interface, press BACK to exit. 

5.3 Radio Check 

Summary of Contents for MD-750

Page 1: ...MD 750 User manual...

Page 2: ...mode switching 3 Digital calling 10 3 1 Group call 3 2 Full call 3 3 Single call 4 Emergency alarm Digital alarm 5 Data command 5 1 short message 5 2 Call alert 5 3 radio detection 5 4 Remote monitor...

Page 3: ...ress and release again the function is turned off VFO MR key P2 key In the main interface switch VFO mode and channel mode A B button P1 button In the main interface switch the primary secondary chann...

Page 4: ...er main interface of analog mode short press key to pop up DTMF dial code box At this time you can manually input DTMF code After input press PTT to start DTMF dialing function D Under the input metho...

Page 5: ...and the frequency difference can be set in the walkie talkie configuration of the menu item Talkaround function in the different frequency mode enter the menu setting to display the icon when the netw...

Page 6: ...ton to delete or return press the OK button to choose corresponding operation Press PTT to call the single call contact for dialing up to 16777214 16777215 full call number Message Inbox Inbox List xx...

Page 7: ...o switch between normal phase N and reverse phase I You can also manually input non standard CTCSS DCS by keyboard press OK key to confirm press BACK key to return Only support analog mode R CTC DCS C...

Page 8: ...d when receiving effectively Press PTT to talk to the other party Single Wait The upper and lower channels are switched by the keyboard The radio works on the main channel and the secondary channel ca...

Page 9: ...off and it can be turned off when it is currently on When On is selected the radio can only be turned on by entering the correct password and pressing OK Change the power on password you can enter a...

Page 10: ...5K 5 0K 6 25K 10K 12 5K 25K 30K 50K In frequency mode press the up and down keys to adjust the frequency step value and the frequency mode scans in this step Ch Type Options analog digital Switch bet...

Page 11: ...wer If there is no voice activity within the predetermined time period the call is terminated 3 2 All call All call is a call made by an individual walkie talkie to all walkie talkies on the channel I...

Page 12: ...s the group call number local alarm And wirelessly send alarm commands alarm mode emergency alarm or emergency alarm W call or emergency alarm w voice to follow can be set Press set as emergency off o...

Page 13: ...the one call contact or press on the home screen to enter the one call number select Intercom Wake Up press OK to start and successfully display Intercom Wake up successfully failure display Intercom...

Page 14: ...e as follows Basic menu suspend time message Scan scan switch scan list Contact call prompt edit manual dialing interphone detection remote monitoring interphone activation interphone remote control o...

Page 15: ...that can possibly cause interference with other devices or systems To avoid such interference turn off the radio in areas where signs are posted to do so DO NOT operate the transmitter in areas that...

Page 16: ...EU Professional version 144 146 430 440MHz EU Amateur version 136 174 400 480MHz USA Professional version 138 174 400 470MHz Canada Professional version Working temperature 10 to 40 Operation Voltage...

Reviews: