WSE1621 Control unit
Cleaning the water filter
9
Tool
Pliers
Fork wrench
Size 32
Cleaning the water filter
Blowing out water
9
The main switch is set to
OFF
X
Disconnect the mains plug.
X
Disconnect all water lines.
X
Connect a purge pump to the water coupling.
X
Blow out water until all of the cooling water has been removed.
X
Remove the pump.
Blowing out water
To ensure the water can be blown out of the lines properly, use the TYROLIT purge pump,
no.10998115.
4.2